Qtech QSW-8200-28F-AC-DC — руководство пользователя: команды для проверки связи [7/25]
Превью страниц
Страница 7 /
25
![Qtech QSW-8200-28T-POEAC- DC Команды отладки и диагностики онлайн [7/25] 481628](/views2/1596649/page7/bg7.png)
User Manual
Chapter 1. Commands for Show 7
www.qtech.ru
Sending 5 56-byte ICMP Echos to 10.1.128.160, using source address 10.1.128.161,
timeout is 2 seconds.
!!!!!
Success rate is 100 percent (5/5), round-trip min/avg/max = 0/0/0 ms
In the example above, 10.1.128.161 is configured as the source address of the ICMP
echo requests, while the destination device is configured to be at 10.1.128.160. The
command receives all the ICMP reply packets for all of the five ICMP echo requests. The
success rate is 100%. It is denoted on the switch “.” for ping failure which means
unreachable link, while “!” for ping success, which means reachable link.
Example 3: Ping with parameters entered interactively.
Switch#ping
VRF name:
Target IP address:10.1.128.160
Use source address option[n]: y
Source IP address: 10.1.128.161
Repeat count [5]: 100
Datagram size in byte [56]:1000
Timeout in milli-seconds [2000]: 500
Extended commands [n]: n
Display Information
Explanation
VRF name
VRM name. If MPLS is not enabled, this field will be left
empty.
Target IP address:
The IP address of the target device.
Use source address option[n]
Whether or not to use ping with source address.
Source IP address
To specify the source IP address for ping.
Repeat count [5]
Number of ping requests to be sent. The default value is
5.
Datagram size in byte [56]
The size of the ICMP echo requests, with default as 56
bytes.
Timeout in milli-seconds [2000]:
Timeout in milli-seconds, with default as 2 seconds.
Extended commands [n]:
Whether or to use other extended options.
Содержание
- Content p.2
- Chapter 1 commands for show p.4
- Clear logging p.4
- History all users max length p.4
- Clear history all users p.4
- Logging p.4
- Logging loghost sequence number p.5
- Logging executed commands p.5
- Show boot files p.10
- Show flash p.10
- Show fan p.10
- Show debugging p.10
- Show history all users p.11
- Show history p.11
- Show logging source p.12
- Show logging executed commands state p.12
- Show logging buffered p.12
- Show running config p.13
- Show memory p.13
- Show switchport interface p.14
- Show running config current mode p.14
- Show startup config p.14
- Show tcp p.15
- Show tcp ipv6 p.16
- Show udp p.17
- Show temperature p.17
- Show telnet login p.17
- Show tech support p.17
- Show udp ipv6 p.18
- Traceroute6 p.19
- Traceroute p.19
- Show version p.19
- Show reload p.21
- Reload cancel p.21
- Reload after p.21
- Chapter 2 commands for reload switch after p.21
- Specified time p.21
- Chapter 3 commands for debugging and diagnosis for packets received and sent by cpu p.23
- Cpu rx ratelimit queue length p.23
- Cpu rx ratelimit protocol p.23
- Cpu rx ratelimit enhanced p.23
- Cpu rx ratelimit channel p.23
- Clear cpu rx stat protocol p.23
- Show cpu rx protocol p.24
- Debug driver p.24
- Cpu rx ratelimit total p.24
Похожие устройства
-
Qtech QSW-1500-20EF-POE-ACТехнические характеристики -
Qtech QSW-1500-19EF-POE-AC V3Описание параметров -
Qtech QSW-1500-10E-POE-DОписание параметров -
Qtech QSW-1500-6E-POE-DПодробное техническое описание -
Qtech QSW-4610Инструкция пользователя -
Qtech QSW-3750 REV. RИнструкция пользователя -
Qtech QSW-3750Руководство по эксплуатации -
Qtech QSW-3420Инструкция по применению -
Qtech QSW-9000-01Руководство по управлению -
Qtech QSW-9000-01Руководство по настройке -
Qtech QSW-9000-01Руководство по настройке управления -
Qtech QSW-9000-01Руководство по командам
Изучите команды для отправки ICMP эхо-запросов и анализа результатов. Узнайте, как настроить параметры пинга для проверки доступности устройств в сети.