CDIL BDY55-CDI Инструкция по эксплуатации онлайн [2/4] 522012

CDIL BDY55-CDI Инструкция по эксплуатации онлайн [2/4] 522012
BDY55 Rev_0 281017E
Continental Device India Pvt. Ltd.
Data Sheet Page 2 of 4
Continental Device India Pvt. Limited
An ISO/TS 16949, ISO 9001 and ISO 14001 Certified Company
PARAMETER SYMBOL TEST CONDITIONS
VALUE
UNITS
MIN MAX
- 0.7
Collector cut-off current
- 5
- 30
Emitter cut-off current - 5
60 - V
Collector-base voltage 100 - V
Emitter-base voltage 7 - V
- 1.1 V
- 2.5 V
Base emitter on voltage - 1.8 V
D.C. Current gain
20 70
10 -
Transition frequency 10 - MHz
ELECTRICAL CHARACTERISTICS (T
A
=25ºC unless otherwise specified)
Collector-emitter cut-off
current
I
CEO
V
CE
=30V, I
B
=0
mA
I
CEV
V
CE
=100V, V
BE
=1.5V
mA
V
CE
=100V, V
BE
=1.5V,
T
C
=150ºC
mA
I
EBO
I
C
=0, V
EB
=7V
mA
Collector -emitter
sustaining voltage
V
CEO(sus)
* I
C
=0.2A, I
B
=0
V
CBO
I
C
=1mA, I
E
=0
V
EBO
I
E
=1mA, I
C
=0
Collector-emitter
saturation voltage
V
CEsat
*
I
C
= 4 A, I
B
= 0.4 A
I
C
= 10 A, I
B
= 3.3 A
V
BE(on)
* I
C
= 4A , V
CE
= 4V
h
FE
*
I
C
= 4A , V
CE
= 4V
I
C
= 10A , V
CE
= 4V
f
T
I
C
= 1 A, V
CE
= 4V
* Pulsed: pulse duration ≤ 350 µs; duty factor = 2%
Скачать