1. General instructions
This instrument complies with IEC 1010-1 (61010-1@IEC: 2001), CAT. II 1000V and CAT. III 600V
overvoltage standards. See Specifications.
To get the best service from this instrument, read carefully this user's manual and respect the
detailed safety precautions.
International symbols used on the Meter and in this manual are explained in chapter 1.1.3
1.1 Precautions safety measures
1.1.1 Preliminary
Measurement category III is for measurements performed in the building installation.
NOTE: Examples are measurements on distribution boards, circuit-breakers, wiring, including
cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, and equipment
for industrial use and some other equipment, for example, stationary motors with permanent
connection to the fixed installation.
Measurement category II is for measurements performed on circuits directly connected to the low
voltage installation.
NOTE: Examples are measurements on household appliances, portable tools and similar equipment.
Measurement category I is for measurements performed on circuits not directly connected to
MAINS.
NOTE: Examples are measurements on circuits not derived from MAINS, and specially protected
(internal) MAINS derived circuits. In the latter case, transient stresses are variable; for that reason,
requires that the transient withstand capability of the equipment is made known to the user.
When using this Multimeter, the user must observe all normal safety rules concerning:
― Protection against the dangers of electric current.
― Protection of the Multimeter against misuse.
For your own safety, only use the test probes supplied with the instrument. Before use, check that
they are in good condition.
1.1.2 During use
If the meter is used near noise generating equipment, be aware that display may become unstable
or indicate large errors.
Do not use the meter or test leads if they look damaged.
Use the meter only as specified in this manual; otherwise, the protection provided by the meter
may be impaired.
Use extreme caution when working around bare conductors or bus bars.
Do not operate the meter around explosive gas, vapor, or dust.