BEHA-AMPROBE BM078 Расширенная инструкция онлайн [6/24] 529183

BEHA-AMPROBE BM078 Расширенная инструкция онлайн [6/24] 529183
5
AmpTip indicators where applicable) as
much as possible to get the best measuring
accuracy. For removal, press the jaw trigger and remove the jaws from the
conductor(s).
Adjacent current-carrying devices such as transformers, motors and conductor wires
may affect measurement accuracy. Keep the jaws away from them as much as
possible to minimize influence.
WARNING
This Clamp-on meter series is designed to directly apply around or remove from
uninsulated hazardous live conductors. But still, individual protective equipment must
be used if hazardous live parts in the installation where measurement is to be carried
out could be accessible. Do not use the meter to measure currents above the rated
frequency (400Hz). Circulating currents may cause the magnetic circuits of the Jaws
reach a hazardous temperature.
Clamp-on AmpTip
TM
ACA; AmpTip
TM
DCA (Models 035 & 037 only)
Input is made via the clamp jaws where best accuracy is specified near the jaw TIP-
CENTER area for low-current measurements of thin conductors. Defaults at ACA.
Press SELECT button momentarily to select DCA for Models 035 & 037.