BEHA-AMPROBE BM078 Расширенная инструкция онлайн [8/24] 529183

BEHA-AMPROBE BM078 Расширенная инструкция онлайн [8/24] 529183
7
zero reading indicates a shorted diode (defective). An over-range display indicates an
open diode (defective). Reverse the test leads connections (reverse biased) across the
diode. The digital display shows over-range if the diode is good. Any other readings
indicate the diode is resistive or shorted (defective).
Beep-Alert & BeepLit
TM
indication: When the display reading drops across 0.850V,
the meter alerts a short beep to signal a reasonable forward voltage drop of common
diodes. However, if the reading further drops below 0.100V, the meter gives a
continuous beep tone together with flashing display backlight to indicate a shorted
diode or a complete wire. It is similar to that of BeepLit
TM
Continuity function but
BeepLit
TM
Diode, instead, is based on voltage threshold to indicate a complete wire.
CAUTION
Using Resistance, BeepLit
TM
Continuity or BeepLit
TM
Diode function in a live circuit
will produce false results and may damage the meter. In many cases, the suspected
component(s) must be disconnected from the circuit to obtain an accurate
measurement reading.