Indoor Unit SiEBE04-507
154 Removal Procedure
2. Removing the indoor unit
1
Remove the indoor unit
from the installation
plate.
3. Removing the heat
exchanger
1
Unfasten the hook of
the pipe fixing plate at
the back of the unit and
pull out the pipe.
2
Widen the auxiliary pipe
by about 10-20
degrees.
3
Unfasten the lower
hook with a flat
screwdriver.
Caution!
When dismounting or
mounting the heat
exchanger, be sure to wear
gloves or wrap it with cloth
before proceeding to the
work. (You may be injured by
the fins.)
Step Procedure Points
(R4402)
Unbending angle:
10-20 deg.
(R4403)
Hook
Lower hook