Daikin FTKS35DVMW9 Сервис мануал онлайн [172/205] 596912

Daikin FTKS20D2VMW Сервис мануал онлайн [172/205] 596898
Outdoor Unit SiEBE04-507
162 Removal Procedure
3
Loosen the 2 screws
and lift the bell mouth to
undo the hooks.
Remove the bell mouth.
4
Loosen the fixing hooks
and release the lead
wire.
Put the lead wire through the
back of the motor when
reassembling. (so as not to
be entangled with the
propeller fan)
Step
Procedure Points
(R3246)
Hooks
Bell mouth
(R3249)
Lead wire Propeller fan