Microlife AG1-10 Инструкция по эксплуатации онлайн [10/68] 72627
![Microlife AG1-10 Инструкция по эксплуатации онлайн [10/68] 72627](/views2/1078071/page10/bga.png)
Содержание
Похожие устройства
- Erisson CVA-918 Инструкция по эксплуатации
- Sony NWZ-E574 8Gb Black Инструкция по эксплуатации
- Microlife AG1-20 Инструкция по эксплуатации
- Erisson CVC-855 Инструкция по эксплуатации
- Sony NWZ-E574 8Gb White Инструкция по эксплуатации
- Microlife AG1-30 Инструкция по эксплуатации
- Erisson CVC-852 Инструкция по эксплуатации
- Philips DS3880W/10 Инструкция по эксплуатации
- Microlife AG1-40 Инструкция по эксплуатации
- Erisson CVC-850 Инструкция по эксплуатации
- Philips DS6600/10 Инструкция по эксплуатации
- Erisson CVA-755 Инструкция по эксплуатации
- Tanita UM-050 Инструкция по эксплуатации
- Hyundai H-1550 Black/Green Инструкция по эксплуатации
- Erisson MGT-4010 Инструкция по эксплуатации
- Tanita UM-051 Инструкция по эксплуатации
- Tanita UM-076 Инструкция по эксплуатации
- Hyundai H-1550 Silver/White Инструкция по эксплуатации
- Tanita BC 545N Инструкция по эксплуатации
- Yamaha MCR-040 Brown Инструкция по эксплуатации
c Tighten the free end of the cuff and close the cuff with the closer d There must be no free space between the arm and thecuff as this would influence the result Clothing must not restrict the arm Any piece of clothing which does e g a pullover must be taken off e Secure the cuff with the closer i n such a way that it lies comfortably and is not too tight Lay the arm on the tabi e I pal m upwards so that the cuff is at the same height as the heart Make sure that the tube is not kinked f Remain seated quietly for two minutes before you begin the measurement Comment If it is not possible to fit thecuff to the left arm it can also be placed on the right one However all measurements should be made using the same arm 4 4 Measuring procedure 4 4 1 Put the chestpiece under the cuff The chestpiece shall not be placed ON or INTO the cuff it shall be placed either under the cuff or 1 2 cm below it The chestpiece is then placed correctly when the Korrotkoff s sound appears strongest loudest Make sure the chestpiece is in contact with skin and above the brachial artery Wear the binaural earpieces properly to check the Korotkoffs sound during measurement Before using the stethoscope be sure there is no crack on the diaphragm earpieces and tubing Any improper setup or damage of the stethoscope will cause distorted sound or poor sound transmission to make inaccurate reading 7