7
PIPING LENGTHS
Heat pump 52 68 80
current new current new current new
Piping Total 35 45 60 60 70 70
length Height 15 15 15 15 15 15
difference
Refrigerant 20m 20m 30m 30m chargeless 40m
charge or more or more or more or more or more
Changed service access
With the current units, both front and top cover must be removed to reach the PCB.
With the new units, only the top panel needs to be removed to reach the PCB.
Wiring changes:
The transmission wiring was changed from : Red/White/Black for Phase/Transmission/Neutral to
Black/White/Red for Neutral/Phase/Transmission.
Multi inverter R-410A series are equipped with an automatic check and correction function for
wiring errors (similar to the current R-22 Multi inverter units)
Changes of indoor pipe diameters (see also chapter 3 indoors)
The liquid pipe diameters of some indoor units are changed :
- 35 class : from 12.7 to 9.5
- 60 class : from 15.9 to 12.7
5. User friendly functions
With R-22 Multi inverter units, following functions were available only on 4MK90H and 4MX80H
units. As a result of widespread demand, they are now available for all classes :
Priority room setting
It is possible to indicate a room as “priority room”, which means that this indoor unit is the
decisive factor in determining cooling or heating mode. The priority room must be set via a
switch in the outdoor unit. Without this priority setting, the decision to switch from cooling to
heating can come from any indoor unit, which is often confusing for customers.
It is also possible to increase the power supplied from the outdoor unit to the “priority room”
by pressing the “powerful button” on the indoor unit.
Powerful
0%
50% 100% 0% 50%
100%
110%
A-room
B-room
C-room
D-room
Distribution performance
Distribution performance
Preference
room
Normal operation Powerful operation
00225•New products•01-12 09-11-2001 11:17 Pagina 8