Installation manual
5
EKUHWBB + EKUHW2WB + EKHWSU150-300B3V3
Domestic hot water tank with option kit for air to water heat pump
system
2 Installation position.
It is advised to connect the 3-way valve as close as possible to
the unit. It can be installed in accordance with one of the
following four configurations.
1 From Daikin Altherma unit
2 To domestic hot water tank
3 To room heating
3 Unpack the 3-way valve body and 3-way valve motor.
1 Sleeve
2 Valve motor cover
3 Screw
4 Scale
4 Install the 3-way valve body in the pipework.
Make sure the shaft will be positioned in such a way that the
motor can be mounted and replaced.
Put the sleeve on the valve and turn the valve to the middle
position of the scale plate.
Check that the valve is positioned as in the figure below. It
should be blocking the outlet connection to the domestic hot
water for 50% and the outlet connection to the room heating also
for 50%.
5 When installing in accordance with figure A or figure D, open the
valve motor cover by loosening the screw and change the
jumper so as to change the rotation direction of the valve.
By default the jumper is factory set to apply for installation in
accordance with figure B and figure C.
6 Push the motor on the motor sleeve.
Make sure not to rotate the sleeve during this action, so as to
maintain the valve position as set during step 4.
7
8 Put the scale on the valve as shown below.
9 Make sure to firmly fix the power supply cord onto the 3-way
valve body with a field supplied cable tie like in illustration below.
10 Perform the wiring in the unit in accordance with the following
figure:
Refer also to the drawing on page 8.
See "Installation of the option kit on the domestic hot water tank" on
page 9 for details on installation in accordance with relevant local and
national regulations.
figure A figure B
figure C figure D
Installation in accordance
with figure A and figure B
Installation in accordance
with figure C and figure D
If the valve is not positioned in this way before mounting
the motor, the valve will give way to both domestic water
and room heating during operation.
1
2
3
1
3
2
1
2
3
1
3
2
1
2
3
4
Installation in accordance with
figure A and figure D
Installation in accordance with
figure B and figure C
Rotation direction of the valve
Domestic hot
water tank
Room
heating
Room
heating
Domestic hot
water tank
Installation in accordance with
figure B and figure C
Installation in accordance with
figure A and figure D
8910
3-way valve
BRN
BLU
BLK
LNY
L
N
Y
DIR
2P
IP41
1x
4P344370-1.book Page 5 Tuesday, April 2, 2013 2:32 PM
4P344370-1B 2019.08

Содержание