12
min. 0.20 m (0.02 bars) and max. 80 m (8 bar) measured at the pump feed inlet; this minimum value
is valid for cold water having a temperature of up to 20°C, for higher temperatures, see the graph on
the last page.
The pumps can also work at a lower supply pressure, under certain operating conditions authorised by
Interpump Group Technical Department.
3.3 - It must be completely airtight and designed in such a way that its seal is guaranteed to last in
time.
3.4 - It must be equipped with a  lter of a suitable size, according to the capacity of the pump, and with
a  ltering degree of min. 300 μm; the  lter must be positioned as close as possible to the pump feed
attachment.
N.B. Even if the water to be used is clean, the  lter must be installed to prevent foreign bodies present
in the plant such as swarf, welding slag or limestone scaling from entering the pump.
3.5 - Flexible piping should be used in the section closest to the pump so as to prevent forced
connections and the transmission of vibrations.
3.6 - It must be designed in such a way as to avoid the pump emptying even only partially when it
comes to a halt.
4 - DELIVERY LINE
The following rules should be respected in designing the DELIVERY line:
4.1 - The inside diameter of the piping must be correctly sized according to the maximum pressure and
capacity so as to ensure the appropriate speed of the  uid and to limit head losses.
4.2 - The  rst section of piping connected to the pump must be  exible, so as to avoid forced connections
and to isolate the vibrations produced by the pump from the rest of the plant.
4.3 - Use should be made of pressure gauges capable of withstanding the pulsating loads typical of
piston pumps, installed in such a way as to measure the pressure directly at the pump manifold.
4.4 - In the design phase, consideration should be given to the head losses on the line, which result in
a drop in working pressure with respect to the pressure measured at the pump.
4.5 - A suitably sized pulsation damper should be installed for applications in which the pulsations
produced by the pump on the delivery line have an undesired or detrimental effect.
Use high-pressure pipes and  ttings suited to the working pressures that may arise
under all operating conditions.
Install a suitably calibrated overpressure valve, as well as the pressure regulating
valve.
5 - MAINTENANCE
5.1 - System maintenance work should be done within the time intervals laid down by the system
manufacturer, who is responsible for the entire assembly in accordance with the law.
5.2 - Correct maintenance prolongs the life of the pump and maintains its maximum performance in
time.
5.3 - All maintenance work should be done by specialized, authorized staff.
5.4 - The pump and its components are to be assembled and disassembled exclusively by authorized