6.2 Use and Maintenance
2.1 After setting up the pump, check the insulation resistance again and
make sure there is no damage to the cable. Turn the pump on to test after
making sure everything is ok. Check to see if the voltage and current on
the control box comply with that on the specified technical parameter of
the pump. After checking the flow rate and there is no vibration and noise,
the unit can be used.
2.2 After the pump has run for 5 hours first time, the pump should be shut
down immediately to check the hot insulation resistance. It should not be
less than 0.5M
2.3 The time interval between shut down and restart is better to be 30 minutes
to prevent damage to the pump due to the incomplete backflow. The
startup times in 24 hours are better to be less than 10 times.
2.4 After normal operation, regular inspection of the voltage, working current
and insulation resistance may extend the pump's service life. If any of the
situations listed below exist, immediately shut the pump down for
troubleshooting.
(1)
The current exceeds 20% of the rate current under rated head and
flow rate.
(2)
When the dynamic water level is below the inlet joint, it will result in
water pumped intermittently or running idly.
(3)
Violent vibration of the pump and pipeline.
(4)
The voltage is too low.
(5)
Fuse in the control box is burned out.
(6)
The hot insulation resistance for motor to the earth is less than 0.5M
(7)
After the pump has been working for a year, or after it has been
submerged for two years, take the pump out to clear sundries or replace
worn parts.