Haier AE122FLAIA Сервис мануал онлайн [93/139] 619469

Haier AU52NFIAKA Сервис мануал онлайн [93/139] 619461
8.7 Testing board for AU52,60NFIAKA:
Commercial Air Conditioner
Model: AU28/342FHAIA,
AU522FIAKA, AU52,60NFIAKA
Mode
Heat
Cool
Stop
Run
Prog.
Enter
Run Stop Defr. Cool Heat
Press button “mode”, the display will change over in the following sequence:
Note: Please connect the wire on power off. Insert the testing board on the CN302 of the
outdoor PCB. The part number is 0010451601.
In addition, we set a testing port CN303 which can be connected to the computer through
another testing device (part number: 0010451800). The distributor can get the testing device
and the testing software from us.
Testing procedure:
1. After the unit powered off, connect the wire of testing board to CN302 port, and then pull
down the communication wire between outdoor and indoor unit.
2. Check if the wiring is right. If yes, power on the outdoor unit.
3. On the operation panel of the testing board, the relative data can be modified.
4. Press “Prog.”, enter data editing mode.
5. Set data “Pr-00” as “0”then data can be edited. Press “Enter” to confirm.
6. The other data can be set according to the requirement like this way.
7. After all the data be modified, set “Pr-00” as “1”.
8. Press “Prog.”, quit out of data editing mode.
9. Note: Data of the chip is very important, the improper modification will cause the main
parts damaged such as compressor. So before modification, please contact with us.
10. After quitting from data editing mode, operation board will display “P r.E” which will flash.
After 3 minutes, it will display “b.P.160”. At this time, pressing the
to reset the
program.
11. After reset, power off the outdoor. For 1~2 minutes, the outdoor release all the electricity,
plug the communication wire between outdoor and indoor to the original position, the
modification is over.
State Display
Frequency Fxx.xx
Current output A xx.x
Voltage on DC side U xxx
Ambient temp 1 xx
Discharging temp 2 xx
Suction temp 3 xx
Defrosting temp 4 xx
Coil temp 5 xx
Indoor unit quantity 6 xx
Open degree of EEV 7 xxx
-90-

Содержание

Скачать