ELECTRICAL CONNECTIONS
The required electrical power supply information is located on the series and rating plate
on the exterior of the unit. Wiring selection must be in accordance with local codes, or in
absence of local code, the National Electrical Code. A disconnect means should be installed
within sight of the unit, when required by code.
Copper wire is recommended for all electrical connections.
When an optional heat kit is installed refer to the electrical requirements in that kit.
The wiring diagram included in the heat kit must be placed over the wiring diagram on the
air handler.
All pertinent information, such as the rating plate, included in the optional heat kit must be
applied to the Air Handler as indicated.
The use of copper connections are recommended inside the control box (see UL 1995,
section 37.9).
WARNING
A MEANS OF STRAIN RELIEF MUST BE INSTALLED TO THIS APPLIANCE AT
THE ELECTRICAL SERVICE ENTRANCE.
When an optional electric heat kit is installed refer to the electrical requirements for that
kit. The ampacity and overcurrent protection shown above is only for "HB" air handlers
installed without a heat kit.
10
Model
No.
Min.
running
Ampacity
208/230
Max.
Over-current
208/230
Blower
Motor
FLA
Blower
Motor
H.P.
2 Ton 1.2/1.2 15/15 0.9 1/8
3 Ton 2.5/2.5 15/15 2.0 1/3
4 Ton 3.3/3.3 15/15 2.6 1/2
5 Ton 4.4/4.4 15/15 3.5 1/2
5 Ton -E 5.0/5.0 15/15 4.0 3/4
Содержание
- Air handler 1
- Installation operation manual 1
- M22 v22 1
- Model hb m20 hb model hb v20 hb installation date 1
- No 0010572323 1
- Seer 2 3 4 5 ton 1
- The information contained in this booklet is subject to change without notice 1
- A b c d e f g h j k 46 22 18 19 10 14 11 17 19 3 118 cm 55 cm 46 cm 50 cm 25 cm 36 cm 30 cm 43 cm 50 cm 8 cm 3
- Of 2 ton 3
- Physical dimensions 3
- Liquid line 4
- Low volt supply 4
- Of 3 ton 4
- Physical dimensions 4
- Suction line 4
- Liquid line 5
- Low volt supply 5
- Of 4 5 ton 5
- Physical dimensions 5
- Suction line 5
- Horizontal left hand instructions 8
- Bl yl bl 11
- For thermostat control environment temperature and air conditioning open stop the wiring diagram as shown diagram 1 thermostat can be mechanical type or programmable type note thermostat c com r ac24v y compressor g fan o 4 way value for detailed thermostat please connect corresponding terminal according to above control specification 11
- For thermostat only control air conditioning open stop hot control environment temperature can adopt different power switch show diagram 2 this mode is control the indoor unit heat pump outdoor unit at the same time no air supply mode if need select the air supply mode switch can adopt multi connect switch or select switch the detailed infor see the following diagram 3 above diagram outdoor unit connection left indoor and outdoor unit power supply respectively right indoor unit power supply 11
- Thermostat wiring 11
- Above diagram outdoor unit connection left indoor and outdoor unit power supply respectively right indoor unit power supply 12
- For thermostat control environment temperature and air conditioning open stop the wiring diagram as shown diagram 4 thermostat can be mechanical type or programmable type note thermostat c com r ac24v y compressor g fan for detailed thermostat please connect corresponding terminal according to above control specification 12
- For thermostat only control air conditioning open stop hot control environment temperature can adopt different power switch show diagram 5 this mode is control the indoor unit cooling only outdoor unit at the same time no air supply mode if need select the air supply mode switch can adopt multi connect switch or select switch the detailed infor see the following diagram 6 12
- Circulating air duct 13
- Orifice change 13
- H black 16
- Hb2400vd1m20 16
- Hb2400vd1v20 16
- Hb3600vd1m22 16
- Hb3600vd1v22 16
- Hb4800vd1m22 16
- Hb4800vd1v22 16
- Hb6000vd1m22 16
- Hb6000vd1v22 16
- Hr60d1var 16
- Indoor unit 16
- Indoor unit blower 16
- Indoor unit model 16
- Model number explanation 16
- Motor speed 16
- Outdoor unit model 16
- Piston size 16
- Table 1 16
Похожие устройства
- Haier HB6000VD1M22 Инструкция по эксплуатации
- Haier HB6000VD1V22 Инструкция по эксплуатации
- Haier HB6000VD1M22-E Инструкция по эксплуатации
- Haier HB6000VD1V22-E Инструкция по эксплуатации
- Haier HC18D1VAR Инструкция по эксплуатации
- Haier HR18D1VAR Инструкция по эксплуатации
- Haier HC24D1VAR Инструкция по эксплуатации
- Haier HR24D1VAR Инструкция по эксплуатации
- Haier HC30D1VAR Инструкция по эксплуатации
- Haier HR30D1VAR Инструкция по эксплуатации
- Haier HC36D1VAR Инструкция по эксплуатации
- Haier HR36D1VAR Инструкция по эксплуатации
- Haier HC42D1VAR Инструкция по эксплуатации
- Haier HR18D1VAR Сервис мануал
- Haier HR24D1VAR Сервис мануал
- Haier HR30D1VAR Сервис мануал
- Haier HR36D1VAR Сервис мануал
- Haier HR42D1VAR Инструкция по эксплуатации
- Haier HR42D1VAR Сервис мануал
- Haier HC48D1VAR Руководство по эксплуатации