Midea MS11M-12HRN1 / MO11M-12HN1 Сервис мануал онлайн [42/55] 624616

Midea MO11M-24HN1 Сервис мануал онлайн [42/55] 624614
Oasis On-off DM12-01.01.09en
42 Service manual
T2T1
High speed
TH
DEFROST
Medium speed
TM
DEFROST
Low speed
TL
DEFROST
Breeze/off No need to compare the T2 and T1
B2: The compressor keeps running for 120 minutes or more, and the difference between evaporator
coil temperature and room temperature meets one of the following:
T2T1
High speed
TH
DEFROST
+2
Medium speed
TM
DEFROST
+2
Low speed
TL
DEFROST
+2
Breeze/off No need to compare the T2 and T1
From the end of the last defrosting mode, if the accumulated time reaches 90 minutes which the AC
is in evaporator high temperature protection mode and the outdoor fan stopped while the compressor
keep working,
Defrosting time
condition
runtimeminute Defrosting timeminute
Case 1
AB1
runtime60 DT1
Case 2
AB1 60runtime80
DT1+1
Case 3
AB1 80runtime95
DT1+2
Case 4
AB1 95runtime110
DT1+3
Case 5
AB1 110runtime120
DT1+4
Case 6
AB2
DT1+5
Case 7
DT1+5
From case1 to case5, If the item B is satisfied before item A and it lasts until the item A is satisfied, it
would be regarded as severe defrosting and the defrosting time is 10 minutes.
If AC enters the defrosting mode from case 1 to case 5 for three times continuously, then the fourth
defrosting time should be
DT1 +5 minutes.

Содержание

Скачать