Simfer F66HB45016 Инструкция по эксплуатации онлайн [18/94] 647089

Simfer F66HB45016 Инструкция по эксплуатации онлайн [18/94] 647089
18
For natural gas connection;
United kingdom type gas connection:
WARNING: The gas hose must not be clamped, bent ar trapped or come
into contact with hat parts of the product. There is the risk of explosion
due to damaged gas hose.
Ventilation Of Room
The air needed for burning is received from room air and the gases emitted
are given directly in room. For safe operation of your product, good room
ventilation is a precondition. If no window or room to be utilized for room
ventilation is available, additional ventilation should be installed. However,
room has a door opening outside, it is no needed to vent holes.
Room Size Ventilating Opening
Smaller than 5 m³ min. 100 cm²
Between 5 m³ - 10 m³ min. 50 cm²
Bigger than 10 m³ no need
In basement or cellar min. 65 cm²
Main Gas Pipe
Gasket
Nut
Natural Gas
Connection Hose
WARNING: Natural gas connection should
be done by authorized service.
For natural gas connection, place gasket
in the nut at the edge of natural gas connection
hose. To install the hose on main gas pipe,
turn the nut. Complete the connection by
making gas leakage control.
l
6 5 /
r
4
F
2

1. Gasket
2. Adapter
3. Gas (safety) hose
4. Valve with 90° outlet
5. Connection piece
6. Gas supply pipe
GB

Содержание

Скачать