Bosch UniversalDistance 50 (0603672800) Инструкция по эксплуатации онлайн [21/396] 666503

Bosch UniversalDistance 50 (0603672800) Инструкция по эксплуатации онлайн [21/396] 666503
Digital laser measureUniversalDistance 50
Measuring accuracy (typical)±2.0 mm
B)
Smallest display unit1 mm
Operating temperature–10 °C to +40 °C
Storage temperature–20 °C to +70 °C
Relative air humidity max.90%
Max. altitude2000 m
Pollution degree according IEC 61010-12
C)
Laser class2
Laser type635 nm, < 1mW
Laser beam diameter (at 25 °C) approx.
at 10m distance9mm
at 20m distance18mm
Automatic switch-off after approx.
Laser20 s
Measuring tool (without measurement)5 min
Weight according to EPTA-Procedure 01:20140.08 kg
Dimensions100 x 42 x 22 mm
Batteries2 x 1.5 V LR03 (AAA)
Battery life approx.
Individual measurements10,000
D)
Continuous measurement2.5 h
D)
A)For measurements from the rear edge of the measuring tool. The working range increases de-
pending on how well the laser light is reflected from the surface of the target (scattered, not re-
flective) and the brighter the laser point is to the ambient light intensity (interior spaces, twi-
light). For distances of less than 20m, a retro-reflective target plate should not be used, as it
can lead to measurement errors.
B)For measurements from the rear edge of the measuring tool, 100% reflectivity of the target (e.g.
a white wall), weak backlighting and 25°C operating temperature. In addition, a deviation influ-
ence of ±0.05mm/m needs to be taken into account.
C)non-conductive soiling only, whereby occasional temporary conductivity caused by condensa-
tion is expected
D)At an operating temperature of 25 °C
The serial number (11) on the type plate is used to clearly identify your measuring tool.
English | 21
Bosch Power Tools1 609 92A 4PE | (25.10.2018)