Graco REACTOR 2 H-30 APH032 Техническая документация онлайн [19/110] 679992

Graco REACTOR 2 H-30 APH032 Техническая документация онлайн [19/110] 679992
Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
Moduledoesnot
havesoftware
Insertasystemtokeninto
theADMmoduleandcycle
thepower.Waituntilthe
uploadiscompletebefore
removingthetoken.
Dialsettowrong
position
EnsuretheHCMdialisset
tothecorrectposition:
H-30=0
H-40=1
H-50=2
H-XP2=3
H-XP3=4
No24VDCsupply
tomodule
Greenlightoneachmodule
shouldbelit.Ifgreenlightis
notlit,checktomakesure
eachCANcableconnection
istight.Verifythepower
supplyisoutputting24
VDC.Ifnot,checkpower
supplywiring.Ifwiringis
okay,replacethepower
supply.
CACMHCMHCMCommunica-
tionError
Looseorbroken
CANcable
ChecktheCANcables
runningbetweenGCA
modulesandtightenof
needed.Iftheproblem
stillpersistsmoveeach
cablearoundtheconnector
andwatchthe󰘱ashing
yellowlightontheGCA
modules.Iftheyellowlight
stops󰘱ashing,replacethe
CANcable.
334946H 19