EM00136457 rev. 1.1 EN
27
Setting the language
Programming
Operation
Allows you to set the language. By default the pump is set to English.
Press to access the item, and then press to set the language.
Press to confirm and return to the main menu.
Paragraph 1 Manual dosage
Programming
Operation
The pump works in constant mode. The flow rate can be adjusted manually
by pressing +
simultaneously.
Display during operation
Paragraph 2 Proportional Dosage to a 0/4-20 mA signal
Programming
Operation
The pump proportionally doses at a signal of (0)4-20 mA. By default, the
pump interrupts the dosage at 4 mA and doses at the maximum set
frequency when it receives 20 mA. These two values can be modified during
programming. The maximum frequency can be modified during operation
by pressing + simultaneously to modify the flow rate.
To view the current reading for the mA input, scroll the menu items to
In mA.
For an input signal of less than 0.2 mA the alarm LED turns on to indicate
the absence of signal.