4. SPECIFICATIONS
Technical parameters
Technical parameters are indicated in table 1,2
Table 1
Parameter
Unit
T-HG2-
Q11T
T-HG3-
Q11T
T-HG3-Q12T
T-HG5-Q12T
Rated power consumption
W
2000
3000
3000
5000
Rated power consumption
(power modes)
W
1000/2000
1500/3000
1000/2000/3000
1500/3000/5000
Rated current
А
8.7
13
13
7.6
Power supply
V/Hz
220-240~/50
220-240~/50
220-240~/50
400 3~/50
Moisture protection class
-
IP24
IP24
IP24
IP24
Electrical protection class
-
Class I
Class I
Class I
Class I
Air consumption
m
3
/h
360
549
600
660
Increase in air temperature
at the air outlet
0
С
98
102
102
102
Heating area
m
2
20
30
30
50
Noise level
dB(A)
36
36
36
41
Device dimensions
mm
230*195*315
265*260*400
300*250*430
300*250*430
Net weight
kg
3.4
4.7
5.7
6.2
Operating conditions
The electrical fan heater is designed for operation in areas with a mild and cold climate in rooms with a
temperature from -20 °C to +40 °C and a relative humidity of up to 80% (at a temperature of +25 °C) in
conditions that exclude the ingress of drops, splashes, and precipitation (climatic version of UHL 3.1
according to GOST15150-69).