1900051 REV.3 Page 7 of 13
DISPENSE WATER
TO COOL THE TANK
Machine can not take more cold water to cool the tank
because it is full. Water needs to be dispensed to allow
room for more cold water to come in and finish cooling
process.
DESCALE TANK
Descale timer elapsed. Time to de-scale the tank.
CHANGE FILTER
Litres output exceeds set value.
Time to change the water filter.
CHECK LOW PROBE
Low water level probe broken (disconnected). Machine
detects high level probe signal but can not detect low level
one. Filling is disabled. Status LED 1 red flash.
THERMISTOR S/C
Temperature sensor (thermistor) is short circuited.
Dispense and heater disabled. Status LED 3 red
flashes.
ELEMENT FAILURE
Heating element is broken. Error is triggered when after
20 minutes of heating and not taking in water temperature
in the tank fails to increase.
Dispense is disabled. Status LED 4 flashes.
THERMISTOR O/C
Temperature sensor (thermistor) is disconnected.
Dispense and heater disabled. Status LED 5 red
flashes.
LOW PRESSURE
Incoming water pressure too low. The error will be reset
after water supply restores.
All boiler functions are active. Status LED 6 flashes.
COMM ERROR
Display board lost communication with boiler PCB (can
not receive serial data about temperature and probes).
All actions cancelled.
MODES OF OPERATION (Service setup setting 5):
The boiler can operate in 4 different modes:
HEAT FILL Standard operation the boiler will take in water until the temperature in the tank
drops, the inlet will close and the heating element is activated. When the temperature reaches
the set temperature the inlet will reopen to take in more water. This cycle will continue until the
Tank is Full.
This mode is used to ensure that the water temperature is controlled within set values.
CONTINUOUS MODE In this mode the boiler will take in water and activate the element until
the tank is full and the temperature has reached the set temperature. Typically used in high
demand situations where the temperature stability is not primary concern.
COOL MODE In this mode the temperature can be adjusted up or down [Set-up function
no.1.] while in operation. Depending on the water level in the tank selecting a lower
temperature will cause either a message to DISPENSE WATER TO COOL THE TANK” or will
automatically take in cooler water to reduce the temperature to the new set temperature. In
applications where selecting different temperatures frequently is required this Cool Mode is
best selected.
Please note that Cool Mode will cause the boiler to operate at half the capacity (eg 10L boiler
to operate as a 5L boiler).