55
CODE
MEANING
AL
Minimum temperature alarm
Remedies:
• check chiller internal temperature
• refer to parameters A1 and A2
Results :
• the system continues to work regularly
AH
Maximum temperature alarm
Remedies:
• check chiller internal temperature
• refer to parameters A3 and A4
Results :
• the system continues to work regularly
id
Alarm micro-port input (only when in “stand-by” and if
parameter i0 is set at 0 or 1)
Remedies:
• identify the causes which enabled this input
• refer to parameters i0 and i1
Results :
• the resulting condition with parameter i0
iA
Alarm compressor protection input (only if parameter i0 is set at
2)
Remedies:
• identify the causes which enabled this input
• refer to parameters i0 and i1
Results :
• the compressor stops
Once the causes which have tripped an alarm are identified and eliminated, the
system returns to normal and regular functioning.
7 DIAGNOSTIC SYSTEM
7.1 Diagnostic system
CODE
MEANING
Error in chiller compartment probe
Remedies: