MAIN ELECTRICAL CHARACTERISTICS (FOS 100 SOLO / )
Input Voltage Range : Vin 90 - 260 Vac
Frequency : 50 - 60 HZ
Power Consumption Range : 6 - 100 W
Power Factor ( Pf) : 0.95 electronic PFC controller
Efficiency : 90% typical
Output:
Power Output Range : 4 channels output (RGBA) 1,5 - 25W per channel
Output Current : 350 mA @ 100% per channel (500mA @ 100% per channel in BOOST Mode)
Output Voltage : Vout 70V
Control Input:
Control Signal : DMX 512
Dimming System :Constant Current PWM
Address Range : DMX 512 channels addressable by display
ACCESSORIES
• Lenses set Spot available for each model
• Lenses set Medium flood available for each model
• Lenses set Wide flood available for each model
• 10XAWG26 multipolar black outdoor cable (Cod. 0509C061)
• M12 female (8 pole) cable connector (Cod. 0520P050)
• M12 male (8 pole) cable connector (Cod 0520P051)
• Z10 Outdoor (IP65) power supply / LED controller (grey) (Cod. 03.LA.020.IP65.26)
• Z10 Indoor (IP20) power supply / LED controller (grey) (Cod. 03.LA.020.26)
• Z1 power supply / LED controller (Cod. 03.LA.009)
• Z4 RACK power supply / LED controller (Cod. 03.LA.014)
• Z8 RACK power supply / LED controller (Cod. 03.LA.075)
• Z1 OUTDOOR power supply / LED controller (Cod. 03.LA.009.IP65)
IMPORTANT SAFETY INFORMATION
Fire prevention:
Never locate the fixture on any flammable surface.
Minimum distance from flammable materials: 10 cm
Replace any blown or damaged fuses only with those of identical value
Prevention from electric shock:
High voltage is present inside the unit.
Unplug the unit prior to performing any operation which involves touching the inside of the unit.
This equipment must be grounded, do not connect to non-grounded supplies.
Use only AC supplies 90-260V, 50-60Hz FOS 100 SOLO IP20 model should never be located in
position exposed to rain or in areas of extreme humidity.
A good air ventilation is essential for proper equipment work.
Safety:
The external surface of the unit may exeed 50°C; never handle the unit until at least 5 minutes
have elapsed since the unit was turned off.
Never install the unit in an enclosed area lacking sufficient air flow.
The ambient temperature should not exeed 40°C and should not be lower than -10°C
FOS 100+ SOLO
The use of a thermal magnetic circuit breaker is recommended for each FOS 100 SOLO unit.
4