Compact ventilation device Tion Breezer Lite
Except in the Tion Breezer Lite Eco variant.
18
Executed command
Number of
beeps, pcs
Switching to "Pairing" mode 2
Smartphone successfully connected to the device 2
Error connecting smartphone to device 3
Switching to "Warning" mode 3
Switching to "Error" mode 3
Filter lifecycle counter reset 4
Reset to factory settings 6
With the power supply connected, when the device is switched off with the "Power/
Airflow rate" control button or with the Tion Remote application, the device switches
to "Standby" mode. In the "Standby" mode the device does not perform its operating
functions: the flap is closed, the fan is off and the heater is off.
Upon a long press of the "Power/Airflow rate" button, if the device is in the "Standby"
mode, it switches to the "Operation" mode. In the "Operation" mode the device performs
its operating functions: air duct flap is open, the fan and heater
18
(if needed) are on.
All parameters retain their set values upon switching to and from "Standby" mode, and in
the event of a power supply outage.
If the device is disconnected from the power supply while in "Operation" mode, upon being
reconnected to power supply the device will be in "Standby" mode for safety reasons.
5.3.4. "Standby" and "Operation" modes
A long press of the "Heating/Pairing" button, while the device is in "Standby" mode,
switches it to "Pairing" mode. In "Pairing" mode the device searches for available
mobile devices supporting wireless Bluetooth technology (hereinafter referred to as a
smartphone) with the Tion Remote application installed.
A detailed description of how to use the Tion Remote smartphone application is given
in Section 5.4.
5.3.5. "Pairing" mode