Compact ventilation device Tion Breezer Lite
The device incorporates a filter lifecycle counter, showing filter replacement warnings on
the front panel light indicators.
When the value of the filter lifecycle counter drops below 30 days, the first LED starts
flashing cyan on the front panel (Figure 5.5). If this indication appears, replace the filter
within 30 days (Section 7.1). The filters are available from the official "Tion" online store
www.tion.global or from authorized dealers.
5.3.8. Filter replacement warnings
Figure 5.5. Filter replacement warning
To reset the counter, while in "Operation" mode press and hold both the "Power/Airflow
rate" and "Heating/Pairing" buttons for at least 3 s. Successful execution of the command
will be confirmed by 4 beeps.
The factory setting of the parameter is 180 days.
WARNING!
Do not reset the counter without replacing the filter. Operating the device with a filter that
is overdue for replacement can decrease the airflow rate, increase fan noise and cause
device failure.
If you want to turn the device off, press the "Power/Airflow rate" button on the device
casing and hold for 3 s. The fan will turn off, the flap will open, and the device will be
switched to "Standby" mode.
WARNING!
If you plan to switch off (depower) the device for a prolonged period, wait for a double
beep after issuing the switch off command, and only then unplug the power cord from
the power socket. Otherwise, the flap may remain open and outside air will be able to
flow through the device into the premises.
5.3.9. Device shutdown, power off