Damixa 777100300 [30/36] Jupiter

Damixa Jupiter с гиг душем и полкой, белый, шт 773500200 [30/36] Jupiter
JUPITER
30
Installation of basin/high mixer with swivel spout/with sidespray
1. Turn o󰀨 the water system.
2. Attach a exible connection to the mixer.
3. Important! Screw the exible eyeliner into the body of the mixer only manually, without any tools
and excessive force to avoid damage.
4. Secure the mixer to the sanitary xture using the supplied hardware.
5. Connect the exible supply pipe to the water supply system: the right supply hose to the cold
water supply, and the left one - hot.
6. It is recommended to connect the mixer with the aerator removed (unscrewed) in order to avoid
clogging at the rst water start.
7. Turn on the water supply system, check tightness of all connections when the mixer is closed.
If necessary, tighten and seal the connections.
8. Open hot and cold water supply for a while, then close water supply and install (twist) the
aerator in place.
9. For mixer with swivel spout. In order to avoid water leaking during usage, please ensure the
bottom portion of body is tight up safely and spout can rotate with some e󰀨ort.
10. For mixers with sidespray. Install hygienic spray by using hose.
Installation of shower/bath and shower mixer with long spout
and shower set/with sidespray/with thermostat
1. Turn o󰀨 the water system. Screw eccentric adapters into the pipes of water supply system,
having previously sealed the threaded part with an insulating material. Select position of the
eccentric adapters, where they coincide and correspond to the connecting position of the mixer.
The mixer should be placed horizontally.
2. It is recommended to connect the mixer with the aerator removed (unscrewed) in order to avoid
clogging at the rst start-up of water.
3. Install decorative sockets on the eccentric adapters and, using a tool with soft lining, attach the
mixer body. Screw the spout for the bath/shower mixer with long spout.
4. Turn on the water supply system, check tightness of all connections when the mixer is closed.
If necessary, tighten and seal the connections.
5. Open hot and cold water supply for a while, then close water supply and install (twist) the
aerator in place.