Zyxel GS2200-24 Руководство пользователя онлайн [272/332] 810932
![Zyxel GS2200-24 Руководство пользователя онлайн [272/332] 810932](/views2/2042737/page272/bg110.png)
Chapter 35 Access Control
GS2200-8/24 User’s Guide
272
temperature TemperatureEventOn 1.3.6.1.4.1.890.1.5.8.55.27.2.1
1.3.6.1.4.1.890.1.5.8.56.27.2.1
1.3.6.1.4.1.890.1.5.8.59.27.2.1
1.3.6.1.4.1.890.1.5.8.60.27.2.1
This trap is sent when the temperature
goes above or below the normal
operating range.
TemperatureEventClear 1.3.6.1.4.1.890.1.5.8.55.27.2.2
1.3.6.1.4.1.890.1.5.8.56.27.2.2
1.3.6.1.4.1.890.1.5.8.59.27.2.2
1.3.6.1.4.1.890.1.5.8.60.27.2.2
This trap is sent when the temperature
returns to the normal operating range.
voltage VoltageEventOn 1.3.6.1.4.1.890.1.5.8.55.27.2.1
1.3.6.1.4.1.890.1.5.8.56.27.2.1
1.3.6.1.4.1.890.1.5.8.59.27.2.1
1.3.6.1.4.1.890.1.5.8.60.27.2.1
This trap is sent when the voltage goes
above or below the normal operating
range.
VoltageEventClear 1.3.6.1.4.1.890.1.5.8.55.27.2.2
1.3.6.1.4.1.890.1.5.8.56.27.2.2
1.3.6.1.4.1.890.1.5.8.59.27.2.2
1.3.6.1.4.1.890.1.5.8.60.27.2.2
This trap is sent when the voltage returns
to the normal operating range.
reset UncontrolledResetEventOn 1.3.6.1.4.1.890.1.5.8.55.27.2.1
1.3.6.1.4.1.890.1.5.8.56.27.2.1
1.3.6.1.4.1.890.1.5.8.59.27.2.1
1.3.6.1.4.1.890.1.5.8.60.27.2.1
This trap is sent when the Switch
automatically resets.
ControlledResetEventOn 1.3.6.1.4.1.890.1.5.8.55.27.2.1
1.3.6.1.4.1.890.1.5.8.56.27.2.1
1.3.6.1.4.1.890.1.5.8.59.27.2.1
1.3.6.1.4.1.890.1.5.8.60.27.2.1
This trap is sent when the Switch resets
by an administrator through a
management interface.
RebootEvent 1.3.6.1.4.1.890.1.5.0.1 This trap is sent when the Switch reboots
by an administrator through a
management interface.
timesync RTCNotUpdatedEventOn 1.3.6.1.4.1.890.1.5.8.55.27.2.1
1.3.6.1.4.1.890.1.5.8.56.27.2.1
1.3.6.1.4.1.890.1.5.8.59.27.2.1
1.3.6.1.4.1.890.1.5.8.60.27.2.1
This trap is sent when the Switch fails to
get the time and date from a time server.
RTCNotUpdatedEventClear 1.3.6.1.4.1.890.1.5.8.55.27.2.2
1.3.6.1.4.1.890.1.5.8.56.27.2.2
1.3.6.1.4.1.890.1.5.8.59.27.2.2
1.3.6.1.4.1.890.1.5.8.60.27.2.2
This trap is sent when the Switch gets the
time and date from a time server.
Table 112 SNMP System Traps (continued)
OPTION OBJECT LABEL OBJECT ID DESCRIPTION
Похожие устройства
- Asko CW 4944S Руководство пользователя
- Asko OM8483S Руководство пользователя
- Asko W4086C.T/2 Руководство пользователя
- Beko OIE 21200 CU Руководство пользователя
- Beko OIG 14101 W Руководство пользователя
- Beko OIE 21200 WU Руководство пользователя
- Canon LBP233dw Руководство пользователя
- Clarion CZ315E 4x50Вт Руководство пользователя
- Clarion CZ505E 4x45Вт Руководство пользователя
- Bosch BBZ123FGI Инструкция по эксплуатации
- Bosch BBZ152HF Инструкция по эксплуатации
- Bosch PHA2302 красный Инструкция по эксплуатации
- Bosch DHZ 5326 Инструкция по эксплуатации
- Libhof FDS-053 Инструкция по эксплуатации
- Libhof FDS-053 Книга рецептов
- Libhof FDS-054 Инструкция по эксплуатации
- Libhof FDS-054 Книга рецептов
- Libhof FDP-08 Инструкция по эксплуатации
- Libhof FDP-08 Книга рецептов
- Libhof FDG-08 Инструкция по эксплуатации