Coolfort CF-3940 Инструкция по эксплуатации онлайн [10/28] 811805

Coolfort CF-3940 Инструкция по эксплуатации онлайн [10/28] 811805
10
ENGLISH
To switch off the convector, press the ON/OFF but-
ton (7) « » on the control panel (5) or the button
(23) « » on the remote control (22) again. The
convector will enter standby mode, and the digital
symbols (15) will show the room temperature and
the symbol (16) «°C» will light up.
Switch off the convector with the switch (3) - the tem-
perature digital symbols (15) will go out.
SETTING ROOM TEMPERATURE
The room heating temperature settings range from
5 °C to 45 °C.
The default heating temperature is 25 °C.
To set the heating temperature for the room, press
one of the buttons (9, 10) « , » on the con-
trol panel (5) or one of the buttons (26) « , »
on the remote control (22). The digital symbols
(15) will flash, and with each press of the buttons
(9 or 10) or (26) the temperature will increase or
decrease by 1 °C and will be saved after 3 seconds
if no further action is taken. After setting the room
heating temperature, the room temperature will be
displayed with digital symbols (15), and the symbol
(16) «°C» will light up.
If the room temperature is 1 °C above the room tem-
perature, the heating will switch off, if the room tem-
perature is 2 °C less than the set temperature, the
heating will switch on.
SETTING POWER LEVEL
Each pressing of the button (8) « » on the control
panel (5) or the button (24) « » on the remote
control (22) allows to select the following modes:
«minimal power mode» (1000 W), «maximal power
mode» (2000 W), «automatic mode», «antifreez-
ing mode».
Each mode will be shown with a corresponding icon
on the control panel (5).
Mode table
Indication Mode
Maximal power mode 2000 W
Minimal power mode 1000 W
Automatic mode. Heating is carried out
to a level of 25 °C, then the convector will
switch off and start heating if the room
temperature drops below 25 °C.
This mode is set by default and will
always be active after switching the con-
vector on.
Antifreezing mode. If the room tempera-
ture drops below 7 °C, the convector
switches on to heat the room.
TIMER
While the convector is on, press the button (11)
« » on the control panel (5) or the button (25) « »
on the remote control (22) to enter the timer set-
ting mode. The digital symbols (15) will be flashing.
Press one of the buttons (9 or 10) « , » on
the control panel (5) or one of the buttons (26)
« , » on the remote control (22) to increase or
decrease the timer by 1 hour and will be saved after
3 seconds if no further action is taken. The symbol
(17) « » will glow.
The timer setting ranges from 0 to 24 hours.
After the timer time setting is finished, the indicator
(17) « » will be glowing constantly until the timer
expires.
While the timer is running, you can also set the room
heating temperature and the desired power level of
the convector.
To switch the timer off, set the timer time to 0 or
switch the convector off with the power switch (3).
To check the set timer time, press the button (11)
« » on the control panel (5) or the button (25) « »
on the remote control (22). If after that no action is
taken in the timer setting mode, the convector will
go into standby mode, and the display will show
the room temperature and the symbol (16) «°C»
will light up.
ANTI-FREEZE FUNCTION
If the convector is in standby mode and the tempera-
ture in the room drops below 7 °C, the convector will
switch on and the « » icon (21) will appear.
When the room temperature reaches 7 °C, the heat-
ing will switch off.
DIGITAL DISPLAY
The digital symbols (15) glow during the convector
operation. If no action is taken for some time, the digital
symbols (15) will go out. Press any button to restore the
brightness to maximum.
CHILD LOCK
Press the touch buttons (9) and (10) « , »
simultaneously on the control panel (5) and hold for
5 seconds to switch the child lock on or off. The LED
display (15) will indicate the activity of the child lock
with the symbol «CH».
You cannot switch the child lock on with the remote
control (22).
Notes:
While the first switching on the heating element
burns, therefore occurrence of a small amount of
smoke or foreign smell is possible. It is normal.
Do not open windows and doors when the unit is
operating; otherwise you will not get the desired
results, due to cold air inflow.
CLEANING AND MAINTENANCE
Disconnect the convector from the mains and let it
cool down before cleaning.
Clean the convector regularly to avoid dust accu-
mulation.