Bosch GLM 40 0601072902 Инструкция к товару онлайн [33/454] 818792
![Bosch GLM 40 0601072902 Инструкция к товару онлайн [33/454] 818792](/views2/2051570/page33/bg21.png)
English | 33
– Structured surfaces (e.g. roughcast, natural stone).
If necessary, use the laser target plate (13) (accessory) on these surfaces.
Inaccurate measurements are also possible where the laser is pointed at target surfaces
diagonally.
Layers of air at different temperatures and indirectly received reflections can also influ-
ence the measured value.
Accuracy Check of the Distance Measurement
You can check the accuracy of the measuring tool as follows:
– Choose a measuring section of approx. 3–10 m in length that is permanently un-
changed, the exact length of which is known to you (e.g. room width, door opening).
The measurement should be taken under favourable conditions, i.e. the measuring
section should be indoors and the target surface for the measurement should be
smooth and reflect well.
– Measure the section ten times in succession.
The deviation of the individual measurements from the mean value must not exceed ±
4mm over the entire measuring section in favourable conditions. Record the measure-
ments in order to be able to compare the accuracy at a later date.
Errors – Causes and Corrective Measures
Cause Corrective measures
Temperature warning(b) flashes, measurement not possible
Measuring tool is outside of the operating
temperature range of -10°C to +45°C.
Wait until the measuring tool has reached
operating temperature
"Error" indicator in the display
Target surface is too reflective (e.g. mirror)
or not reflective enough (e.g. black mater-
ial), or ambient light is too bright.
Use the laser target plate(13)
The laser beam output(12) and/or recep-
tion lens(11) are fogged up (e.g. due to a
rapid temperature change).
Wipe the laser beam output(12) and/or re-
ception lens(11) dry with a soft cloth
Measurement result implausible
Target surface reflection not distinct (e.g.
water, glass).
Cover the target surface
Laser beam output(12) and/or reception
lens(11) are covered.
Keep the laser beam output(12) and/or re-
ception lens(11) clear
Bosch Power Tools 1 609 92A 5DX | (27.01.2020)
Похожие устройства
- Bosch GLM 40 Professional 0.601.072.900 Инструкция к товару
- Bosch GLM 50 0.601.072.200 Инструкция по эксплуатации
- Bosch Zamo II 0.603.672.620 Инструкция по эксплуатации
- Bosch Zamo III Set 3 адаптера 0.603.672.701 Инструкция по эксплуатации
- Condtrol Smart 20 1-4-096 Инструкция по эксплуатации
- Condtrol Smart 40 1-4-097 Инструкция по эксплуатации
- Condtrol Vector 100 1-4-100 Инструкция по эксплуатации
- Condtrol Vector 60 1-4-104 Инструкция по эксплуатации
- Condtrol Vector 80 1-4-099 Инструкция по эксплуатации
- Condtrol XP3 Pro 1-4-103 Инструкция к товару
- RGK 770057 Инструкция к товару
- Deko GLE-40 065-0240 Руководство по эксплуатации
- Deko LRD110-40m065-0205-1 065-0205-1 Инструкция по эксплуатации
- Deko LRD110-70m 065-0206 Инструкция по эксплуатации
- Deko LRE110-70m 065-0174 Паспорт
- DELI DL4168 0.05-40м, точность ± 3мм, дисплей 1.7 дюймов 102961 Инструкция
- DELI DL4169 102962 Инструкция
- DELI DL4170 диапазон 0.05~80 м, точность: ±3 мм 102963 Инструкция
- Levenhuk LX1000 81417 Инструкция к товару
- Levenhuk LX1500 81418 Инструкция к товару