EAV56344-02 03/21
|
The insert is shown here in operation in combina-
tion with a push-button module. More details on
how to operate the various modules can be found
in the relevant operating instructions.
Switching loads on/off (1-gang insert)
Switching loads on/off (2-gang insert)
Right push-button: Channel 1
Left push-button: Channel 2
Calling up lightscenes (1-gang insert)
(only for push-button module, 2-gang)
Standard scenes
All devices are delivered from the factory with preset-
tings for a lightscene.
Operating the insert
S1: Light on
S2: Light off
< 0,5 s
< 0,5 s
< 0,5 s
< 0,5 s
Controlling loads from another location
with transmitting devices via PlusLink.
For example:
Central unit insert with module
Side controller Plus, 1-gang/2-gang
Mechanical push-button
External sensor
Example operation 1:
When the push-button module on the central unit insert
is pressed, all loads in the PL lines are controlled togeth-
er:
Short push-button action (< 0.5 s): switch on/off
A Relay switch insert in PL line 1
B Central unit insert with module
Example operation 2:
|
When a mechanical push-button is used, we rec-
ommend connecting only one insert. With two or
more inserts, simultaneous switching of the loads
is no longer guaranteed.
A Relay switch insert
B Mechanical push-button
B
A
A
PL4 PL3
PL2
PL1
<
0,5 s
<
0,5 s
B
A
<
0,5 s
PL
If you have technical questions, please contact the Cus-
tomer Care Centre in your country.
se.com/contact
Technical data
Nominal voltage: AC 220/230 V , 50/60 Hz
Nominal current: 10 AX, cosφ = 0.6
Switching capacity per
channel
Incandescent lamps: 2200 W
HV halogen lamps: 2000 W
LV halogen lamps with
wound transformer:
500 VA
Electronic transformers: 1050 W
Capacitive load: 10 A, 140 μF
Energy-saving lamps: 100 VA
Motor load: 1000 VA
MTN5162-0000: If channel 1 is loaded with 10 A, then
channel 2 may only be loaded with 4 A. The total load
on both channels may not exceed 14 A.
Neutral conductor: required
Outputs:
MTN5161-0000 1 make contacts
MTN5162-0000 2 make contacts
Connecting terminals: Screw terminals for max.
2x 2.5 mm
2
or 2x 1.5 mm
2
Protection
Only use the following circuit breakers:
MTN5161-0000 MTN5162-0000
Schneider
Electric 10 A 23614 16 A 23617
ABB 10 A S201-B10 16 A S201-B16
ABL Sursum 10 A B10S1 16 A B16S1
Hager 10 A MBN110 16 A MBN116
Legrand 10 A 03268 16 A 03270
Siemens 10 A 5SL61106 16 A 5SL61166
Dispose of the device separately from
household waste at an official collection
point. Professional recycling protects people
and the environment against potential nega-
tive effects.