LG UB42 [12/19] Set temp
![LG UB18 [12/19] Set temp](/views2/1108269/page12/bgc.png)
12 Ceiling Concealed Duct Type Air Conditioner
Operating Instructions
ZONE
Operation unit Program set
Room Temp
MED
LO
AUTO
JET
Heater
Defrost
Filter
Humidify
Out door
Time
Timer
On
Set no. Time
Off
01 03 05 07 09 11 13 15 17 19 21 23
1234
AUTO SWING OPERATION
FAN SPEED
SUB FUNCTION
SET TEMP
HI
Preheat
Preheat
ZONE
Operation unit Program set
Room Temp
MED
LO
AUTO
JET
Heater
Filter
Humidify
Out door
Time
Timer
On
Set no. Time
Off
01 03 05 07 09 11 13 15 17 19 21 23
1234
AUTO SWING OPERATION
FAN SPEED
SUB FUNCTION
SET TEMP
HI
Defrost
HI
ZONE
Operation unit Program set
Room Temp
MED
LO
JET
Heater
Defrost
Filter
Preheat
Humidify
Out door
Time
Timer
On
Set no. Time
Off
01 03 05 07 09 11 13 15 17 19 21 23
1234
AUTO SWING OPERATION
FAN SPEED
SUB FUNCTION
SET TEMP
AUTO
To raise the Temperature.
To lower the Temperature.
Cold Cool Proper Warm Hot
Soft Dry Operation Mode
5
This air-conditioner is set to the hot start control in order not
to discharge the cold air during the heating operation. This
time, the remote controller indicates ‘Preheat’.
6
If the outdoor temperature is too low during the heating
operation, this air-conditioner is set to the defrosting
operation and the remote controller indicates ‘Defrost’.
For Heat Pump Type
7
Soft Dry Operation is used to remove the humidity softly without overcooling the room, specially when
the humidity is already low.
The indoor fan speed is automatically set to the low. But you can change it. Soft dry operation cancels
and becomes the cooling operation if you press the operation mode selection button.
Auto Operation Mode (Cooling Type)
8
The temperature and fan speed are automatically set by the electronic controls based on the actual
room temperature. If you want to change the set temperature, close the door on the remote control and
press the Room Temperature Setting buttons. The cooler or warmer you feel, the more times
(up to two times) you should press the button. The set temperature will then be changed.
The temperature can be set within a range of -2~2 by 1 level.
(This indication will be shifted to the initial
Auto Mode Display state after 5 seconds.)
During Auto Operation:
❏ You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule.
❏ If the system is not operating as desired, manually switch to another mode. The system will not
automatically switch from the cooling mode to the heating mode, or from heating to cooling, it must be
done by manually resetting.
Содержание
- Air conditioner 1
- Owner s manual 1
- For your records 2
- Precaution 2
- Read this manual 2
- Table of contents 2
- Caution 3
- English 3
- Safety precautions 3
- Warning 3
- Caution 4
- Ceiling concealed duct type air conditioner 4
- Safety precautions 4
- English 5
- Owner s manual 5 5
- Safety precautions 5
- Ceiling concealed duct type air conditioner 6
- Name and function of parts 6
- Product introduction 6
- What to do before operation 6
- Auto operation 7
- Cooling operation 7
- English 7
- Heating operation 7
- Operation mode 7
- Owner s manual 7 7
- Soft dry operation 7
- Type 1 type 2 7
- Wired remote controller 7
- Auto swing 8
- Ceiling concealed duct type air conditioner 8
- Fan speed 8
- Heater defrost filter 8
- Operating instructions 8
- Operation 8
- Preheat humidify out door 8
- Set temp 8
- Set the current time and day of the week 8
- Sub function 8
- Auto swing 9
- English 9
- Fan speed 9
- Heater defrost filter 9
- Hour min 9
- Operation 9
- Preheat humidify out door 9
- Program set 9
- Set clr 9
- Set temp 9
- Sub function 9
- Weekly programming 9
- Auto swing 10
- Ceiling concealed duct type air conditioner 10
- Fan speed 10
- Heater defrost filter 10
- Holiday setting 10
- Operation 10
- Preheat humidify out door 10
- Set temp 10
- Sub function 10
- Timer setting 10
- 03 05 07 09 11 13 15 17 19 21 23 11
- Auto swing 11
- Cooling heating operation mode 11
- English 11
- Fan speed 11
- Heater defrost filter 11
- Operation 11
- Operation mode 11
- Operation unit program set 11
- Owner s manual 11 11
- Preheat humidify out door 11
- Room temp 11
- Set no time 11
- Set temp 11
- Sub function 11
- Auto operation mode cooling type 12
- Auto swing operation 12
- Ceiling concealed duct type air conditioner 12
- Defrost 12
- Fan speed 12
- Filter humidify out door 12
- For heat pump type 12
- Heater 12
- Heater defrost filter 12
- Heater defrost filter humidify out door 12
- Off 01 03 05 07 09 11 13 15 17 19 21 23 12
- Operating instructions 12
- Operation unit program set 12
- Preheat 12
- Preheat humidify out door 12
- Set temp 12
- Soft dry operation mode 12
- Sub function 12
- Auto operation mode heat pump type 13
- Auto swing operation 13
- English 13
- Fan operation mode 13
- Fan speed 13
- Heater defrost filter 13
- If the system is not operating as desired manually switch to another mode the system will not automatically switch from the cooling mode to the heating mode or from heating to cooling then you must set the mode and the desired temperature again 13
- Preheat humidify out door 13
- Set temp 13
- Sub function 13
- The system will automatically switch from the cooling mode to the heating mode or from heating to cooling when you select auto opration mode 13
- The temperature can be set within a range of 18 c 30 c by 1 c 13
- This function is used to circulate room air without cooling or heating 13
- To lower the temperature 13
- To raise the temperature 13
- You can switch the indoor fan speed 13
- Auto restarting function 14
- Ceiling concealed duct type air conditioner 14
- Child lock function 14
- Fan auto 14
- Operation procedure 14
- Air filters 15
- English 15
- Indoor unit 15
- Maintenance and service 15
- Caution turn off the circuit breaker when the air conditioner is not going to be used for a long time dirt may collect and may cause a fire 16
- Ceiling concealed duct type air conditioner 16
- Helpful information 16
- Maintenance and service 16
- Operation tips 16
- When it is not going to be used for a long time 16
- When the air conditioner is not going 16
- When the air conditioner is to be used again 16
- Call the service immediately in the following situations 17
- English 17
- Maintenance and service 17
- Owner s manual 17 17
- Troubleshooting tips save time and money 17
Похожие устройства
- Texet TB-566 Purple Инструкция по эксплуатации
- Sony VAIO VGN-BX195XP Инструкция по эксплуатации
- LG UB42H Инструкция по эксплуатации
- Digma E625 Silver+карта 500 руб Инструкция по эксплуатации
- LG UB48 Инструкция по эксплуатации
- Sony VAIO VGN-BX196SP Инструкция по эксплуатации
- Sony VAIO VGN-BX196VP Инструкция по эксплуатации
- LG UB48H Инструкция по эксплуатации
- PocketBook Touch 2 623 Burgundy Инструкция по эксплуатации
- Sony VAIO VGN-BX196XP Инструкция по эксплуатации
- LG UB60 Инструкция по эксплуатации
- Sony PRS-T3 Black+карта Инструкция по эксплуатации
- Sony VAIO VGN-BX197XP Инструкция по эксплуатации
- LG URNU18GVJA2 Инструкция по эксплуатации
- Sony VAIO VGN-BX294VP Инструкция по эксплуатации
- PocketBook 623 Touch 2 Black/White Инструкция по эксплуатации
- LG URNU24GVJA2 Инструкция по эксплуатации
- Sony VAIO VGN-BX295SP Инструкция по эксплуатации
- Texet TB-721HD 4Gb Red Инструкция по эксплуатации
- LG URNU76GB8A2 Инструкция по эксплуатации