Trotec OZ-ONE включая сертификат калибровки 3510006110 Инструкция к товару онлайн [10/12] 855489
![Trotec OZ-ONE включая сертификат калибровки 3510006110 Инструкция к товару онлайн [10/12] 855489](/views2/2092372/page10/bga.png)
10 EN
ozone meter OZ-ONE
Maintenance and repair
Battery change
A battery change is required when a battery indication lights up
on the display(11), when erratic values are indicated on the
display or when the device can no longer be switched on. See
chapter Operation.
Cleaning
Clean the device with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Do not use any
sprays, solvents, alcohol-based cleaning agents or abrasive
cleaners, but only clean water to moisten the cloth.
Repair
Do not modify the device or install any spare parts. For repairs
or device testing, contact the manufacturer.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
If the measurement value display is flickering or only party
visible, the batteries have to be changed. See chapter
Operation, section "Inserting the batteries".
The following error messages can be displayed in the
measurement value display for the ozone concentration(16):
Error message Cause Remedy
rEg High measured
values- sensor
regenerates
Wait until the
regeneration phase is
over.
This process may take
up to one minute.
Once the device
returns to the normal
measuring mode, you
can proceed with the
next measurement.
If this is not the case,
please contact the
customer service.
Er1 Defective sensor Please contact the
customer service.
oL2 Message appears in
measurement value
display Ozone
concentration(16):
Measured ozone value
is outside the device's
measuring range.
At first, wait for the
measured value to
drop and check
whether the
measurement value
display returns back
to normal.
If this is not the case,
please contact the
customer service.
Message appears in
measurement value
display Humidity(19):
Measured humidity
value is outside the
device's measuring
range, temperature is
displayed correctly
and alternating with
the error message.
Message appears in
measurement value
display
Temperature(19):
Measured
temperature value is
outside the device's
measuring range,
humidity is displayed
correctly and
alternating with the
error message.
Похожие устройства
- Iek УКД D=37мм IP55 YUK10-37-55 Инструкция к товару
- Iek УКД D=40мм IP66 YUK10-40-66 Инструкция к товару
- Энкор 10314 Инструкция к товару
- Антиток УНП-10 БД до 10 кВ, 11 кг 315058 Инструкция
- Petzl i'd evac самоблокирующееся спусковое для высотных работ D020CA01 Инструкция
- Chint NJR2-45D 84А 45кВт 489026 Паспорт
- Chint NJR2-55D 103А 55кВт 489027 Паспорт
- Chint NJR2-7.5D 15А 7.5кВт 489019 Паспорт
- Доступная Автоматика 380в 11квт 22a modbus rtu DA40 22-A-3P3 Руководство
- Доступная Автоматика 380в 45квт 90a modbus rtu DA40 90-A-3P3 Руководство
- Innovert номинальный ток 110 а, питание управления 220в ac, rs-485 SSD553A43E Быстрый Пуск
- Innovert номинальный ток 110 а, питание управления 220в ac, rs-485 SSD553A43E Инструкция
- Innovert номинальный ток 12 а, питание управления 24в dc, rs-485 SSD222D21E Быстрый Пуск
- Innovert номинальный ток 12 а, питание управления 24в dc, rs-485 SSD222D21E Инструкция
- Innovert номинальный ток 15 а, питание управления 24в dc, rs-485 SSD752D43E Быстрый Пуск
- Innovert номинальный ток 15 а, питание управления 24в dc, rs-485 SSD752D43E Инструкция
- Innovert номинальный ток 22 а, питание управления 24в dc, rs-485 SSD113D43E Быстрый Пуск
- Innovert номинальный ток 22 а, питание управления 24в dc, rs-485 SSD113D43E Инструкция
- Innovert номинальный ток 30 а, питание управления 220в ac, rs-485 SSD153A43E Быстрый Пуск
- Innovert номинальный ток 30 а, питание управления 220в ac, rs-485 SSD153A43E Инструкция