8. INSTALLATIONAND OPEARATION
8.1 Precautions before installation
The electric water heater should be positioned and installed according to the user's environmental conditions and
comprehensive consideration of the following factors:



Try to avoid places prone to vibration;

the hot water pipeline should be insulated to reduce the heat loss of the pipeline;

To facilitate future repairs, maintenance, relocation, etc., a certain space must be reserved around the installation
The bearing capacity of the installation surface should be no less than 4 times the total mass of the electric water
heater to ensure safety;

devices;
The location of the leakage protection switch should be placed in a safe place where there will be no risk of electric
shock and where water cannot be splashed. Check the leakage protection switch used in the electric water heater by
visual inspection and using specialized measuring devices (phase meter, test pen, grounding resistance meter, etc.) to
ensure that the live wire and neutral wire are installed correctly and grounded reliably, and ensure that the grounding

Check whether the capacity of the electricity meter, wires, and leakage protection switch meets the requirements of
the electric water heater;

0.6 MPa. Check the tap water pressure witha pressure gauge, if the tap water pressure is greater than 0.6 MPa,
a pressure reducing valve should be installed on the inlet pipe;
Electric water heaters should be installed indoors where the ambient temperature is above 0
.
EN 5
7. PRODUCT DIMENSIONS
A
C
D
Figure C
Main Dimensions, mm
156
B
79
C
255
D
248