8.2 INSTALLATION STEPS
NOTICE:
The water heater must be installed by the company's authorized personnel.The supplied accessories must be used
during installation; unauthorized replacement is not allowed. If the above rules are not complied with, the
company will not be liable for any direct or indirect losses caused thereby.
Step 1:Installation preparation
●
instruments.
● Check whether the electric water heater is in good condition, and whether the accompanying documents and
accessories are complete.
● Read this manual carefully to understand the functions, operation methods, installation requirements and installation
methods of the electric water heater.
● Check the user's power supply, it must be 220V- 50Hz power supply;The location of the leakage protection switch
should be placed in a safe place where there will be no danger of electric shock and where water cannot be splashed.
Check the leakage protection switch used in the electric water heater by visual inspection and using specialized
measuring devices (phase meter, test pen, grounding resistance meter, etc.) to ensure that the live wire and neutral
wire are installed correctly and grounded reliably; Check whether the electric meter capacity, leakage protection
switch, electric wire can meet the power requirements of the water heater, see the "technical performance
parameters"; Check the tap water pressure with a pressure gauge, if the tap water pressure is greater than 0.6 MPa, a
pressure reducing valve should be installed on the inlet pipe.
●
direct sunlight, rain and wind;Try to avoid places prone to vibration;Try to shorten the distance between the electric
reduce the heat loss of the pipeline;The bearing capacity of the installation surface should not be less than 4 times the
under the electric water heater to ensure safety.
● For thosedo not meet the installation requirements of electric water heaters, professional installation personnel
be refused.
Step 2. Installation operation
● The installation of the electric water heater should use the attached accessories, and professional installation
personnel should not replace, omit or modify at will.
● During installation, attention should be paid not to damage the safety structure of the building.
●
● The water heater must be installed vertically.
●
CAUTION:
The ground wire must be reliably grounded, otherwise it may cause safety accidents.
The leakage protection switch must be installed in a dry place where cannot be sprayed by water.
EN 6
Похожие устройства
- Atmor CONCEPT 3.5 KW SHOWER 3195635 инструкция
- Atmor CONCEPT 5 KW COMBI (душ + кран) 3195640 инструкция
- Atmor LIBERTY 3.5 KW SHOWER 3195630 Инструкция по эксплуатации
- Atmor LIBERTY 5 KW COMBI (душ + кран) 3195634 Инструкция по эксплуатации
- Atmor LIBERTY 5 KW TAP 3195633 Инструкция по эксплуатации
- Atmor SELECT 7KW белый 3195642 паспорт
- RISPA Norma 20 квт. белый RGNW-20 Паспорт
- Haier ES50V-Color GA0S41E1CRU Инструкция к Haier ES50V-Color GA0S41E1CRU
- Haier ES80V-Color GA0S40E1CRU Инструкция к Haier ES50V-Color GA0S41E1CRU
- Atlantic MIXTE 80 854019 Инструкция к Atlantic MIXTE 80 854019
- Kospel WW-100 TERMO HIT WW-100 Инструкция к Kospel WW-100 TERMO HIT
- Metalac DIRECT G 100 368004 Руководство по эксплуатации
- Metalac DIRECT G 200 368002 Руководство по эксплуатации
- Metalac DIRECT G plus 150 368001 Руководство по эксплуатации
- Metalac DIRECT WL 100 левое подключение 367999 Руководство по эксплуатации
- Metalac DIRECT WL 150 левое подключение 176162 Руководство по эксплуатации
- Metalac DIRECT WL 200 левое подключение 170350 Руководство по эксплуатации
- Metalac DIRECT WR 100 правое подключение 368000 Руководство по эксплуатации
- Metalac DIRECT WR 150 правое подключение 368008 Руководство по эксплуатации
- Metalac DIRECT WR 200 правое подключение 176363 Руководство по эксплуатации