Once you have selected the proper site for the water heater, determine the
spots for the holes for fasteners (according to the specifications of the product
you have acquired). Drill two holes in the wall of the appropriate depth using a
drill that is suitable for the size of the fasteners, install the fasteners in the
holes and then hang an electric water heater on it (see Figures 3, 4).
Connecting to the water main
1. The water heater must be connected to the water main with a minimum
pressure of 0.1 MPa and a maximum pressure of 0.7 MPa.
NOTE!
The water heater is a product, in which water pressure corresponds to water
pressure in the water main. If water pressure in the water main exceeds 0.7
MPa, a pressure-reducing valve must be installed before the heater to ensure
that water pressure does not exceed 0.7 MPa.
2. To connect the water heater to the water main, 12 mm (G1/2) diameter
pipes are used.
3. Use rubber seal gaskets on the threaded ends of the pipes in order to
prevent leakage when connecting the pipes.
4. Screw the safety relief valve on the inlet nozzle, which is marked in blue and
has a water flow direction arrow in such a way that that the water flow
coincides with the direction of the arrow on the valve body. Put the water
drainage tube* (water may appear during heating) on the pressure relief port of
the safety relief valve to allow water drainage into the sewer (see Fig. 6) (the
tube must be directed downwards and must not be bent).
5. To facilitate the maintenance of the water heater, it is recommended to
install a drain tap and a tee between the cold water inlet pipe and the safety
valve. This tee will help to drain the water from the water heater faster. For
convenience, it is recommended to connect a water drain hose*to the cut-off
tap of the tee. This hose will allow you to direct the water drained from the
water heater to the sewer or other place of your choice.
6. Connect the required number of water consumption points to the outlet
nozzle marked in red.
7. Open the shut-off valve of the water main and one of the outlet valves.
When the tank is full, which is prompted by water leaking from the outlet valve,
close the outlet valve and make sure that all connectors are tight.
* not included in the scope of delivery. New hoses must be used, old hoses
must not be reused
WARNING!
Do not operate the water heater without a safety relief valve installed on the
inlet nozzle.
WARNING!
The pressure-relief device must be activated on a regular basis to remove the
scale and ensure proper operation.