Timberk R20 40л. T-WSS40-R20-V Инструкция по эксплуатации онлайн [25/48] 857582

Timberk R20 40л. T-WSS40-R20-V Инструкция по эксплуатации онлайн [25/48] 857582
IM2022
25
2. To connect the water heater to the water main, 12 mm (G1/2) diameter pipes
are used.
3. Use rubber seal gaskets on the threaded ends of the pipes in order to prevent
leakage when connecting the pipes.
4. Screw the safety relief valve on the inlet nozzle, which is marked in blue and
has a water flow direction arrow in such a way that that the water flow coincides
with the direction of the arrow on the valve body. Put the water drainage tube*
(water may appear during heating) on the pressure relief port of the safety relief
valve to allow water drainage into the sewer (see Fig. 6) (the tube must be
directed downwards and must not be bent).
5. To facilitate the maintenance of the water heater, it is recommended to install
a drain tap and a tee between the cold water inlet pipe and the safety valve.
This tee will help to drain the water from the water heater faster. For
convenience, it is recommended to connect a water drain hose*to the cut-off tap
of the tee. This hose will allow you to direct the water drained from the water
heater to the sewer or other place of your choice.
6. Connect the required number of water consumption points to the outlet nozzle
marked in red.
7. Open the shut-off valve of the water main and one of the outlet valves. When
the tank is full, which is prompted by water leaking from the outlet valve, close
the outlet valve and make sure that all connectors are tight.
* not included in the scope of delivery. New hoses must be used, old hoses
must not be reused
WARNING!
Do not operate the water heater without a safety relief valve installed on the inlet
nozzle.
WARNING!
The pressure-relief device must be activated on a regular basis to remove the
scale and ensure proper operation.
WARNING!
If water in the installation place has significant content of calcium, manganese
or iron salts, it is necessary to install a suitable filter in the water supply system
in order to reduce the amount of scale in the tank and on the heating element.
Connection to the electric main
WARNING!
Before connecting the tank water heater, make sure the water heater is properly
grounded. Proper grounding is important to minimize electrocution and fire
hazard. The power cord is equipped with a plug with a grounding contact. The
product must be used with a properly grounded main socket.

Похожие устройства