Master B 70CED 4011.819 Инструкция к Master B 70 CED 4011.819 онлайн [7/187] 860192

Master B 70CED 4011.819 Инструкция к Master B 70 CED 4011.819 онлайн [7/187] 860192
5
GB
kerosene to tank,stir, and drain again. This will prevent excess
debris from clogging lters during future use.
4. Replace fuel cap or drain plug. Properly dispose of old and
dirty fuel. Check with local automotive service stations that
recycle oil.
5. If storing, store heater in dry place. Make sure storage place
is free of dust and corrosive fumes.
IMPORTANT: Do not store kerosene over summer months for
use during next heating season. Using old fuel could damage
heater.
PREVENTATIVE MAINTENANCE SCHEDULE
WARNING: Never service heater while it is plugged in, operating, or hot. Severe
burns and electrical shock can occur.
Item How Often How To
Fuel tank Flush every 150-200 hours of operation or as
needed
See Storing, Transporting,or Shipping.
Air output andlint lters Replace every 500 hours of operation or once a
year
See Air Output, Air Intake, and Lint Filters, page
7
Air intake lter Wash and dry with soap and water every 500
hours of operation or as needed
See Air Output, Air Intake, and Lint Filters, page
7
Fuel lter Clean twice a heating season or as needed See Fuel Filter, page 6
Spark plug Clean and regap every 600 hours operation
orreplace as needed
See Spark plug, page 6
Fan blades Clean every season or as needed See Fan, page 9
Motor Not required/permanently lubricated
TROUBLESHOOTING
WARNING: Never service heater while it is plugged in, operating, or hot. Severe
burns and electrical shock can occur.
OBSERVED FAULT POSSIBLE CAUSE REMEDY
Heater ignites, but ame-out con-
trol shutsoff heater after a short
period of time
1. Wrong pump pressure
2. Dirty air output, air intake, and lint lters
3. Dirty fuel lter
4. Dirt in nozzle
5. Dirty photocell lens
6. Bad ame-out control
1. See Pump Pressure Adjustment, page
10.
2. See Air Output, Air Intake and Lint Filters, page
10
3. See Fuel Filter, page 8
4. See Nozzle, page 11
5. Clean photocell lens
6. Replace ame-out control
Heater will not ignite, but motor
runs for ashort period of time
1. Wrong pump pressure
2. Carbon deposits on spark plug and/
orimproper gap
3. Dirty fuel lter
4. Dirt in nozzle
5. Water in fuel tank
6. Electronic ignitor not grounded (earthed)
7. Bad electronic ignitor
1. See Pump Pressure Adjustment, page 7
2. See Spark Plug, page 6
3. See Fuel Filter, page 6
4. See Nozzle, page 8
5. Drain and ush fuel tank with clean kerosene.
See Storing, Transporting, or Shipping.
6. Make sure electronic ignitor mountingis tight
7. Replace electronicignitor
Motor does not start when heater
is pluggedin, fan rotates slowly or
does not turn
1. Flame-out control not reset
2. Binding pump rotor
1. Reset ame-out control button, see Figures 5
and 6, page 4
2. If fan is hard to turn, see Pump Rotor, page 9
WARNING: High voltage!
PREVENTATIVE MAINTENANCE SCHEDULE
TROUBLESHOOTING

Похожие устройства

Скачать