Kuppersberg FG 69 W [42/82] Setting the minima

Kuppersberg FG 45 B [42/82] Setting the minima
42
TECHNICAL PASSPORT ENGLISH
Built-in hob
 remove the covers and the
spreaders,
 with a 7 mm socket spanner un-
screw and remove the injectors,
 replace the injectors with those
supplied corresponding,
 to the gas available (see burner
and injector characteristics Table),
 replace the various parts pro-
ceeding in reverse.
Remember to replace the old rating
plate with the new one (supplied).
Whenever the gas pressure used is
different (or variable)
from that used, install a pressure
regulator which conforms to the local
regulations in force on the input pipe.
Setting the minima
The ame on the small output is
regulated in the factory. When the
injectors have been replaced or there
are special mains pressure conditions,
it may be necessary to regulate the
minimum again. The operations neces-
sary to perform this operation are the
following:
 light the burner
 turn the knob to the minimum
position
 take out the knob (and gasket if
there is one)
 using a suitably sized screwdriver
turn the regulation screw inside or by
the side of the tap shaft until a small
regular  ame is obtained
 put the knob back on and turn it
quickly rom the maximum position to
the minimum position, checking that
the  ame does not go out
 for burners with safety valve
make sure that the regulation obtained
is suf cient to maintain heating of the
thermocouple. If it is not increase the
minimum.
Regulation of minimum for LPG
To regulate the minimum for LPG,
completely tighten (clockwise) the
screw inside or next to the gas tap pin.
The operations described above
can easily be performed whatever the
positioning or fastening of the hob to
the cabinet.
THE BURNERS REQUIRE NO
REGULATION OF THE PRIMARY AIR.