Kuppersberg FG 69 B [38/82] Connection diagram

Kuppersberg FG 45 B [38/82] Connection diagram
38
TECHNICAL PASSPORT ENGLISH
Built-in hob
 The manufacturer shall not be
responsible for any damages that may
arise if used without a grounded line.
 Warning: The device may only be
connected to the mains electricity by an
authorized and competent person and
the product warranty only begins after
the correct installation. The manufac-
turer may not be held responsible for
any damages arising from operations
carried out by unauthorized persons.
 Warning: The electric cable
should not be crushed, folded, com-
pressed, or come into contact with hot
parts of the device. In case of any dam-
age to the electric cable, it should be
replaced by a competent electrician.
Otherwise, there is a danger of electric
shock, short circuit, or  re!
 Warning: Mains supply informa-
tion should be the same as the informa-
tion on the type label of the unit. The
type label is on the rear housing of the
device.
 Warning: Before performing any
operation on the electrical installa-
tion, disconnect the product from the
electricity. There is a danger of electric
shock.
 If it is not possible to separate
the poles in the mains supply, a sepa-
ration unit (fuses, line safety switches,
contactors) with a minimum 3 mm con-
tact distance should be connected and
all poles of this separation unit must
be adjacent (not over) to the stove per
IEE regulations. Failure to follow this
instruction may result in operational
problems and void the device warranty.
CONNECTION DIAGRAM
L1+L2 Single-Phase 3x4 mm
2
32 A
L1- L2 Two Phase 3x2,5 mm
2
16 A

Содержание

Скачать