Zalman ZM770-XT [3/6] Plugging the main power connector p1 into the motherboard while the product is connected to the ac power source may cause damage to the motherboard make sure that the connectors are connected to their designated locations and that the connectors are not oriented in the wrong direction when connecting the dc output connectors if the power on led fails to light up when the main power button is pressed after completing the installation procedure some devices may be connected incorrectly or the motherboard may be faulty
![Zalman ZM660-XT [3/6] Plugging the main power connector p1 into the motherboard while the product is connected to the ac power source may cause damage to the motherboard make sure that the connectors are connected to their designated locations and that the connectors are not oriented in the wrong direction when connecting the dc output connectors if the power on led fails to light up when the main power button is pressed after completing the installation procedure some devices may be connected incorrectly or the motherboard may be faulty](/views2/1111404/page3/bg3.png)
※
The specifications of any product may change without any prior notice to improve performance.
2
4. Specifications
※ To ensure a safe and easy installation, please read the safety precautions above and the
following notes.
▣ Plugging the Main Power Connector P1 into the motherboard while the product is connected to
the AC power source may cause damage to the motherboard.
▣ Make sure that the connectors are connected to their designated locations, and that the
connectors are not oriented in the wrong direction when connecting the DC output connectors.
▣ If the Power ON LED fails to light up when the main power button is pressed after completing
the installation procedure, some devices may be connected incorrectly or the motherboard may
be faulty.
3. Installation Guidelines
AC Input Range
AC Input Range
(Rated)
PFC Type
Power Factor
Efficiency
Inrush Current Limit
(@ Cold start at 25℃)
DC Output Voltage
Regulations
At Full
Load
At Full
Load
DC Output Ripple &
Noise
Voltage 100VAC ~ 240VAC ±10%
Frequency 50Hz ~ 60Hz
ZM660-XT ZM770-XT
115VAC 9.5A 11A
230VAC 4A 5A
Active PFC
99% Max
ZM660-XT ZM770-XT
115VAC 80A 80A
230VAC 60A 60A
88% Max @230VAC, Typical Load
Vout Regulation Range
+3.3VDC ±5% +3.14V ~ +3.47V
+5VDC ±5% +4.75V ~ +5.25V
+12V1DC ±5% +11.4V ~ +12.6V
+12V2DC ±5% +11.4V ~ +12.6V
+12V3DC ±5% +11.4V ~ +12.6V
+12V4DC ±5% +11.4V ~ +12.6V
-12VDC ±10% -10.8V ~ -13.0V
+5VSB ±5% +4.75V ~ +5.25V
ZM660-XT
Vout
Output Load Rating
Combined
I
min
I
max
I
peak
Power
ZM770-XT
Vout
Output Load Rating
Combined
I
min
I
max
I
peak
Power
+3.3V 0.8A 30A 35A
+5V 0.5A 30A 35A
155W
+12V1 0.5A 20A 22A
+12V2 0.5A 20A 22A
+12V3 0.5A 20A 22A
636W
660W
+12V4 0.5A 20A 22A
-12V 0.0A 0.8A
22.1W
+5VSB 0.1A 2.5A 3.5A
+3.3V 0.8A 30A 35A
160W
+5V 0.5A 30A 35A
+12V1 0.5A 20A 22A
+12V2 0.5A 20A 22A
+12V3 0.5A 20A 22A
720W
770W
+12V4 0.5A 20A 22A
-12V 0.0A 0.8A
22.1W
+5VSB 0.1A 2.5A 3.5A
Ambient Temperature
Operation 0℃ ~ +40℃
Stored -20℃ ~ +80℃
Ambient Humidity
Operation 5%RH ~ 95%RH
Stored 5%RH ~ 95%RH
Dimensions
180mm(L) * 150mm(W) * 86mm(H)
Protection
Over-Voltage Protection (OVP)
Over-Current Protection (OCP)
Under-Voltage Protection (UVP)
Short-Circuit Protection (SCP)
Over-Temperature Protection (OTP)
Vout Regulation Range
+3.3VDC 50mV
+5VDC 50mV
+12V1&2DC 120mV
+12V3&4DC 120mV
-12VDC 120mV
+5VSB 50mV
▣▣
Electrical & Mechanical Specifications
Содержание
- Caution 2
- Components 2
- Safety precautions 2
- Warning 2
- Electrical mechanical specifications 3
- Installation guidelines 3
- Plugging the main power connector p1 into the motherboard while the product is connected to the ac power source may cause damage to the motherboard make sure that the connectors are connected to their designated locations and that the connectors are not oriented in the wrong direction when connecting the dc output connectors if the power on led fails to light up when the main power button is pressed after completing the installation procedure some devices may be connected incorrectly or the motherboard may be faulty 3
- Specifications 3
- To ensure a safe and easy installation please read the safety precautions above and the following notes 3
- Zm dc1 4
- Trimon 2d 3d convertible lcd monitors 5
- Versatile tower enclosure 5
- Zalman s recommendations 5
- 80plus 6
- Bronze certification 6
- Certifications 6
- For inquiries 6
- International safety standards and emc certifications 6
- Product warranty 6
- Weee rohs 6
Похожие устройства
- Sony VAIO VPCEB4B4E Инструкция по эксплуатации
- Liebherr UWKes 1752-20 Инструкция по эксплуатации
- Zalman ZM500-RS Инструкция по эксплуатации
- Rowenta Easy Stylist SF6042D0 Инструкция по эксплуатации
- Sony VAIO VPCEB4A4E Инструкция по эксплуатации
- Zalman ZM400-ST Инструкция по эксплуатации
- Rowenta Opt iliss SF3132D0 Инструкция по эксплуатации
- Sony VAIO VPCEB3Z1R Инструкция по эксплуатации
- Zalman ZM500-ST Инструкция по эксплуатации
- Sony VAIO VPCEB3Z1E Инструкция по эксплуатации
- Babyliss Expert 2100 D321E Инструкция по эксплуатации
- Zalman ZM600-ST Инструкция по эксплуатации
- Rowenta CV4750F0 Инструкция по эксплуатации
- Sony VAIO VPCEB3S1R Инструкция по эксплуатации
- Zalman ZM-K400G Инструкция по эксплуатации
- Sony VAIO VPCEB3S1E Инструкция по эксплуатации
- Rowenta CV7730D0 Инструкция по эксплуатации
- Rowenta CV8340F0 Инструкция по эксплуатации
- Zalman ZM-GM4 Инструкция по эксплуатации
- Sony VAIO VPCEB3M1R Инструкция по эксплуатации