for 1 liter of hot water, take 1 tablespoon of citric acid and mix well;
pour the solution into the tank and put it on the base of the humidifier (water from the tank will
automatically fall into the base of the device);
leave the humidifier for 10-12 hours - do not turn it on;
after the time has passed, remove the solution from the device along with the exfoliated parts of the salt
coating;
if it is difficult to remove plaque - use a special brush for the base of the humidifier (if this is not
supplied, you can use a toothbrush). For the tank - pour 0.5-1 cups of dry rice into cold water or a
cooled citric acid solution and shake until the plaque is peeled off;
rinse all internal parts of the device with cool water;
use a humidifier as usual after the procedure.
How to clean ceramic filter:
Clean and activate the ceramic ball filter after using 1000L water regularly. Depend on water quality, if
ceramic balls are dirty, the filter needs to be cleaned more frequently.
It can be dipped in vinegar about 5 minutes. Then rinse it cleanly with clean water.
Put the filter under the sun for 4~6 hours.
You can purchase replacement filters.
10. TROUBLESHOOTING
Malfunction
Possible cause
Solution
Poor atomizing (insufficient
productivity)
The unit is operating in
the low atomizing mode (low
atomizing frequency)
It is not a malfunction. Switch the
device into the intensive mode of
operation
The atomizer is clogged
Clean the atomizer.
Temperature of water in the
tank is low
Set maximum productivity mode.
The humidifier’s productivity will
go up after a while.
No atomizing
The power cord is poorly
connected to the outlet
Connect the power cord into
the outlet carefully
There is white patches from the
water on objects around the
humidifier (salts, separating out
from water)
White patches have
formed on the membrane
Clean the humidifier’s membrane
with a special brush
There is a lot of salts in the water
(calcium and magnesium)
Use filtered water
Steam has a bad smell
Stale water is used
Clean the unit according to
the cleaning and servicing
instructions and fill the tank
with fresh and filtered water
Remains of stale water or waste
have accumulated in the unit’s
case or the atomizer
During the operation of the
device, condensate is forming on
the upper part of the humidifier
and on surrounding objects
High humidification intensity is
set.
Decrease the humidification
intensity
Room humidity and
room temperature are high
During the operation of the device
water appears next to it
High humidification intensity is
set.
Decrease the humidification
intensity
The water tank is badly installed
on the unit’s base and there is a
gap between them.
Turn off the unit and make sure
the water tank is installed
correctly on the base, without any
gaps between the tank and the
base.
White patches have formed on
the membrane and in grooves for
water (in the unit’s base).
Clean the unit according to the
cleaning and servicing
instructions.
Water appears next to the
humidifier, when it is off
Water tank is leaking
Contact an
authorized service center