Timberk T-HU6-A19E-W 5л, белый Инструкция по эксплуатации онлайн [21/0] 882839
![Timberk T-HU6-A19E-W 5л, белый Инструкция по эксплуатации онлайн [21/0] 882839](/views2/1908551/page21/bg15.png)
IM2022
21
for 1 liter of hot water, take 1 tablespoon of citric acid and mix well;
pour the solution into the tank and put it on the base of the humidifier (water from the tank will
automatically fall into the base of the device);
leave the humidifier for 10-12 hours - do not turn it on;
after the time has passed, remove the solution from the device along with the exfoliated parts of the salt
coating;
if it is difficult to remove plaque - use a special brush for the base of the humidifier (if this is not
supplied, you can use a toothbrush). For the tank - pour 0.5-1 cups of dry rice into cold water or a
cooled citric acid solution and shake until the plaque is peeled off;
rinse all internal parts of the device with cool water;
use a humidifier as usual after the procedure.
How to clean ceramic filter:
Clean and activate the ceramic ball filter after using 1000L water regularly. Depend on water quality, if
ceramic balls are dirty, the filter needs to be cleaned more frequently.
It can be dipped in vinegar about 5 minutes. Then rinse it cleanly with clean water.
Put the filter under the sun for 4~6 hours.
You can purchase replacement filters.
10. TROUBLESHOOTING
Malfunction
Possible cause
Solution
Poor atomizing (insufficient
productivity)
The unit is operating in
the low atomizing mode (low
atomizing frequency)
It is not a malfunction. Switch the
device into the intensive mode of
operation
The atomizer is clogged
Clean the atomizer.
Temperature of water in the
tank is low
Set maximum productivity mode.
The humidifier’s productivity will
go up after a while.
No atomizing
The power cord is poorly
connected to the outlet
Connect the power cord into
the outlet carefully
There is white patches from the
water on objects around the
humidifier (salts, separating out
from water)
White patches have
formed on the membrane
Clean the humidifier’s membrane
with a special brush
There is a lot of salts in the water
(calcium and magnesium)
Use filtered water
Steam has a bad smell
Stale water is used
Clean the unit according to
the cleaning and servicing
instructions and fill the tank
with fresh and filtered water
Remains of stale water or waste
have accumulated in the unit’s
case or the atomizer
During the operation of the
device, condensate is forming on
the upper part of the humidifier
and on surrounding objects
High humidification intensity is
set.
Decrease the humidification
intensity
Room humidity and
room temperature are high
During the operation of the device
water appears next to it
High humidification intensity is
set.
Decrease the humidification
intensity
The water tank is badly installed
on the unit’s base and there is a
gap between them.
Turn off the unit and make sure
the water tank is installed
correctly on the base, without any
gaps between the tank and the
base.
White patches have formed on
the membrane and in grooves for
water (in the unit’s base).
Clean the unit according to the
cleaning and servicing
instructions.
Water appears next to the
humidifier, when it is off
Water tank is leaking
Contact an
authorized service center
Содержание
- Eng ulrtasonic humidifier 12 1
- Kz ауа ылғалдағышы 22 1
- Ru ультразвуковой увлажнитель воздуха 2 1
- Модель model t hu6 a19e w цвет color w белый white 1
- Руководство по эксплуатации instruction manual пайдалану жөніндегі нұсқаулық 1
- Appliance to avoid damage during use 12
- Before starting up for the first time check that the 12
- Read these instructions carefully before using the 12
- Specifications on the product comply with the power supply specifications 12
- Authorized service center or similar qualified personnel 14
- Do not pull on the power cord grasp the plug do not twist and do not wind it on anything 14
- Membrane while it is operating due to the high oscillation frequency the membrane becomes very hot 14
- Power cord near heating appliances or flammable or combustible substances 14
- Remove the electrical plug from the power outlet in 14
- The following cases before draining or filling the tank with water before assembly disassembly and cleaning or if you do not use it before mounting dismounting the humidifier elements before moving the humidifier to another location install the humidifier on a flat dry surface 14
- To avoid burns do not touch the humidifier 14
- To avoid risk of electric shock do not place the 14
- When disconnecting the appliance from the mains 14
- Www timberk ru 32
Похожие устройства
- Electrolux EWH 80 Royal Flash Inverter Руководство по эксплуатации
- Electrolux EWH 100 Royal Flash Inverter Руководство по эксплуатации
- Endever Costa-1097 Руководство по эксплуатации
- Blackton Bt CM1114 Руководство по эксплуатации
- Midea MFD60S360Wi Руководство по эксплуатации
- Regent NTS 50V 15K (RE) Руководство по эксплуатации
- Electrolux PURE I9 PI92-4ANM Руководство по эксплуатации
- Hiberg F 91 FGW White Руководство по эксплуатации
- Weissgauff BDW 4573 D Wi-Fi Руководство по эксплуатации
- Electrolux EOB7S31Z Руководство по эксплуатации
- Шведский Стандарт Сириус 2.02.02.060.1 Руководство по эксплуатации
- Шведский Стандарт Сириус 2.02.02.060.3 Руководство по эксплуатации
- Шведский Стандарт Сириус 2.02.02.060.5 Руководство по эксплуатации
- Шведский Стандарт Кастор 2.03.02.060.3 Руководство по эксплуатации
- Шведский Стандарт Кастор 2.03.02.060.5 Руководство по эксплуатации
- Шведский Стандарт Кастор 2.03.02.070.1 Руководство по эксплуатации
- Шведский Стандарт Кастор 2.03.02.070.3 Руководство по эксплуатации
- Шведский Стандарт Кастор 2.03.02.070.5 Руководство по эксплуатации
- Candy CP 6F51LS-08 Руководство по эксплуатации
- Midea MFD60S510Bi Руководство по эксплуатации