39
8 Close the front panel.
9 Connect all cables, then turn on the LinkStation.
10
For RAID 0
Navigate to Drives - RAID in Advanced Settings. Select the array with the error, then click Delete RAID Array.
Navigate to Drives - Drives. Choose the new drive (the unformatted one) and format the drive. After formatting
the drive, change the RAID mode.
For RAID 1
Navigate to Drives - RAID in Advanced Settings. Select the array with the error, then click Recover RAID Array.
Follow the procedure on the screen to complete the hard drive replacement.
Note: While the RAID array is rebuilding, the LinkStation's power LED may turn off for a while. The unit is still
running however. To check the progress of the rebuild, log in to Settings.
For JBOD
Navigate to Drives - Drives in Advanced Settings. Format the new drive and create a shared folder before use.