Application menu
File
Photos Folder: set a directory for captured images.
Videos Folder: set a directory for recorded videos.
Options
Resolution: set image resolution.
Date/Time: hide or display date and time of capture during preview.
Language: change the language of the user interface.
XY Guide: hide or display a grid on images.
Full screen mode: go full screen.
Capture
Photo: capture an image.
Video: record a video.
Capturing an image
Click the corresponding icon on the toolbar or select Photo from the Capture menu.
Recording a video
Click the corresponding icon on the toolbar or select Video from the Capture menu.
Sequence capture
Click the corresponding icon on the toolbar. A dialog window will appear where you
can set a number of parameters for sequence capture. Click the Photo radio button
to set the time to begin capturing images, interval between them and the total
number of images. Click the Video radio button to set the time to begin recording
videos, their duration, interval between them and the total number of clips.
Calibration
Before calibrating the microscope, turn the grid display on. To do so, select On from
Options > XY Guide. By default, the grid is visible. Place the calibration scale on the
stage and focus your view. Make sure that the vertical axis of the grid is parallel to
scale divisions and capture an image. Double-click the image thumbnail to open it in
a separate window.
Click the corresponding icon on the toolbar to begin calibration. Using your mouse,
choose two points on the image (you have to know the actual distance between these
two points). Once you choose the second point, a dialog window will open, where you
have to enter the known distance in the Actual dimension eld. The application will
automatically calculate the magnication of the image. Click OK to close the dialog
window. The calculated magnication will be displayed in the Magnication eld.
Note: Chosen points should form a horizontal line.
You can check calibration results by measuring the same distance with the Straight line
tool. Click the measurements icon, choose the Straight line tool and draw a similar line on
the image. If the measured distance is equal to the actual distance, calibration has been
successful.
Recalibration
The calibration process has to be repeated if the magnication or focus has been
changed during observations.
Click the corresponding icon on the toolbar again and select Reset picture
magnication from Reset magnication. Repeat the calibration process, as described
above. Change the magnication and capture a few images. Double-click one of the
thumbnails to open the resulting image in a preview window. Click the calibration
icon on the toolbar and select Set picture magnication from Set magnication.
Enter the current magnication in the dialog window that appears and click OK.
If you want to use the same magnication when capturing images in the future, click
the calibration icon on the toolbar and select Set capture magnication from Set
magnication.
Measurements
It is recommended to calibrate the system before proceeding with measurements.
Straight line. Press and hold the le mouse button to start drawing a line. Release the
le mouse button to complete the line.
Continuous Line. Press and hold the le mouse button and draw a line. Release the
le mouse button to complete the segment. You can continue adding more segments
to the free-form line.
Radius Circle. Draw a straight line on the image. The application will automatically
calculate the radius, as well as circumference and area of the corresponding circle.
Diameter Circle. Draw a straight line on the image. The application will automatically
calculate the diameter, as well as circumference and area of the corresponding circle.
Three Points Angle. Press and hold the le mouse button to draw a line on the image.
Capture an image
Start and stop video
recording
Sequence capture (you can set the time to begin capturing images or videos,
interval between them, video duration and the number of images or videos
to be captured)
Full screen mode. To exit full screen mode, press Escape on your keyboard
or double-click anywhere on the screen
Save as
Copy to clipboard
Copy le
Previous image
Next image
Repeat the last action
Draw
Text
Measurement
Calibration
Undo the last action
Похожие устройства
- Dreame L20 Ultra Complete Руководство по эксплуатации
- Dreame L30 Ultra Руководство по эксплуатации
- Code Origin Enhanced (GXB01WE) White Руководство по эксплуатации
- Dreame Bot L10s Ultra (RLS6LADC) Руководство по эксплуатации
- Ника Т5У+/З Руководство по эксплуатации
- Ника Т5У/А Руководство по эксплуатации
- Ника Т5У+/А Руководство по эксплуатации
- Ника Т5У/З Руководство по эксплуатации
- Ника Т5У/Г Руководство по эксплуатации
- Ника Т5У/СН Руководство по эксплуатации
- Dreame RLS6L Руководство по эксплуатации
- Dreame L10 Ultra Руководство по эксплуатации
- Dreame Cordless Vacuum Cleaner R10 Pro Black Руководство по эксплуатации
- Dreame Cordless Vacuum Cleaner R10 White Руководство по эксплуатации
- Dreame Cordless Vacuum Cleaner R20 Grey Руководство по эксплуатации
- Dreame Wet and Dry Vacuum H12 Core Black Руководство по эксплуатации
- Dreame Wet and Dry Vacuum H12 Black Руководство по эксплуатации
- Rombica Shaver SRX-002 Руководство по эксплуатации
- Rombica Shaver SRX-001 Руководство по эксплуатации
- Aquanet Нота 50 White (00175670) Руководство по эксплуатации