Magnit RMS-1600 [8/20] Removing mineral deposit

Magnit RMS-1600 [8/20] Removing mineral deposit
Steam clothes and bottom of clothes, Please handle bottom side; Refer D & E, Or use Mini
Iron board to assist you such as picture F.
D
E
F
Pressing with steam
We recommend you follow this procedure at least once per month to extend
machine working periods;
1. Turn the Switch to “off”or “0” position.
2. Unplug the unit from the power outlet.
3. Ensure the steamer to cool for at least 30 minutes.
4. Remove the Hose and shorten the Telescopic Pole, then set them aside.
5. Remove and drain the Water Tank. Rinse the water tank with fresh water, and drain completely.
6. Drain the steamer by removing the Drain Plug and emptying the contents.
7. Flush the unit by filling the Water flume and the Hose Connector with fresh water and
draining completely. Put the Drain Plug back.
8. Wrap the Hose around the Telescopic Pole one time. Place the Steam spout on the
steam hanger.
9. Store in a cool and dry place.
Cleaning and storage
Different water sources contain minerals and the sediment may cause mineral deposit in the steamer and
affect the free flow of steam. To reduce the occurrence of mineral deposit in the steamer, demineralized or
distilled water is recommended.
To remove the mineral deposit, please follow below procedure:
1. Turn the unit off, and unplug the power cord.
2. Remove the hose and pole from the unit.
3. Drain the Water flume and empty water from the Water Tank.
4. Mix a solution of 50% vinegar and 50%water or Citric acid .
5. Slowly pour the water vinegar or citric acid into the Hose Connector or water tank about 0.6 Liters;
6. Let unit power on and work 5 6 minutes.
7. Cool unit about 30 minutes, Drain the solution out of the Water Reservoir by removing the drain plug
and allowing the liquid to drain into a sink or tub.
8. Drain the solution out of the Hose Connector by tilting the unit over a sink or tub and pouring the water
out of the Hose Connector.
9. Pour clean water in the Hose Connector or Water flume inlet and drain it. Repeat this step until the
vinegar odor dissipates.
10. Reassemble the unit and operate normally.
IF THIS PROCEDURE DOES NOT RETURN THE UNIT TO NORMAL OPERATION, THE UNIT
MAY NEED SERVICING.
Removing mineral deposit
8