Kawasaki NINJA 650R (2005) [521/625] Electrical system 16 29

Kawasaki NINJA 650R (2005) [521/625] Electrical system 16 29
ELECTRICAL SYSTEM 16-29
Battery
Charging Condition Inspection
Battery charging condition can be checked by measuring
battery terminal voltage with a digital voltmeter [A].
Remove:
Seat (see Seat Removal in the Frame chapter)
Battery Cable Cap (see Battery Removal)
Disconnect the battery terminals.
CAUTION
Be sure to disconnect the negative (–) cable first.
Measure the battery terminal voltage.
NOTE
Measure with a digital voltmeter which can be read one
decimal place voltage.
If the reading is 12.8 V or more, no refresh charge is re-
quired, however, if the read is below the specified, refresh
charge is required.
Battery Terminal Voltage
Standard:
12.8 V or more
Terminal Voltage (V) [A]
Battery Charge Rate (%) [B]
Good [C]
Refresh charge is required [D]
Refreshing Charge
Remove the battery [A] (see Battery Removal).
Do refresh charge by following method according to the
battery terminal voltage.
WARNING
This battery is sealed type. Never remove sealing
cap [B] even at charging. Never add water. Charge
with current and time as stated b elow.