Tesy CC 3012 E05 R [4/40] Adjust the heating period in the following consequence

Tesy CB 1507 E01 R [4/40] Adjust the heating period in the following consequence
4 Usage and Storage Instructions EN
EN
OPERATION
Turning-on
Put the plug into the socket, turn thermostat knob
clockwise and turn the appliance on as follows:
Only button (I) is turned-on – light heating –
MIN (W);
Only button (II) is turned-on – medium heating –
MED (W);
Both buttons are turned-on – intense heating –
MAX (W);
Power values of the corresponding levels (MIN(W),
MED(W), MAX(W)) are shown in table.
Model MAX(W) MED(W) MIN(W)
1005 1000 W 600 W 400 W
1006 1000 W 600 W 400 W
1506 1500 W 900 W 600 W
1507 1500 W 900 W 600 W
1508 1500 W 900 W 600 W
2008 2000 W 1200 W 800 W
2009 2000 W 1200 W 800 W
2010 2000 W 1200 W 800 W
2011 2000 W 1200 W 800 W
2012 2000 W 1200 W 800 W
2510 2500 W 1500 W 1000 W
2511 2500 W 1500 W 1000 W
2512 2500 W 1500 W 1000 W
2513 2500 W 1500 W 1000 W
2514 2500 W 1500 W 1000 W
3012 3000 W 1800 W 1200 W
3013 3000 W 1800 W 1200 W
3014 3000 W 1800 W 1200 W
To turn o the appliance turn o the two buttons and
take the plug out of the socket outlet.
Thermoregulator adjustment
Power switch and thermoregulator should be set to
maximum position until the desired room temperature
is reached. Then turn thermoregulator switch in the
opposite direction till red light indicator goes down.
Thermoregulator may stay in that position after that.
Immediately after room temperature falls below
thermoregulator value thermal switches are turned on
automatically until set temperature is reached. In that
way room temperature is steady with minimum energy
consumption.
If you want to prevent temperature fall in the room
below 0 degrees Centigrade adjust thermostat switch in
its initial position and turn on the two power buttons.
24-hours timer models (“T”)
Adjust the heating period in the following consequence:
Set the clock to the correct
time. If it is 10 oclock turn the
gures dial so that the mark is
positioned to the gure of 10.
Turn the gures dial only in the direction indicated
with arrows! Adjust the period of operation of the
appliance by pushing black keys to the center – every one
of them corresponds to 15 minutes period. Sector of the
pushed keys will correspond to the period of operation of
the radiator in automatic mode every day.
Important : Plug should always be connected to the
socket outlet!
In order to change programmable period of
automatic operation turn black keys backwards and
adjust new periods of operation.
If you do not want the appliance to operate in
programmable mode push all black keys to the
center of the gures dial. To turn o the radiator in
that case you have to pull the plug out of the socket.
In that way unnecessary operation of the timer is
avoided.
Thermal fan models (“V”)
Models equipped with a 500W thermal fan oer
faster achievement of desired temperature and better
ventilation in the room. Thermal fan may function
separately or together with oil-lled radiator. Thermal
fan is positioned in the bottom part of the front panel
of the radiator and is turned on by a switch positioned
in that part of the panel. Cold air is sucked through the
grating in the front part of the front panel and hot air is
released in the room through the grating positioned in
the bottom side part of the radiator panel. Desired room
temperature with thermal fan operation is adjusted by
thermoregulator of the radiator in the above mentioned
manner. For the normal operation of the thermal fan
it is necessary that air passes unobstructedly through
inlet and outlet grating. Electrical device is intended
for domestic use in premises with low level of dust
pollution. Dust is accumulated after certain period
of operation. In is necessary to check periodically
level of pollution and if needed to consult the service
organization for cleaning.