Citizen SR-282 [15/16] Full message
![Citizen SR-282 [15/16] Full message](/views2/1012170/page15/bgf.png)
15 / 15
DEG STAT
LSL=
[ ]
70
.
CPK
LSL
DEG STAT
CPK
[ ]
0
. 72590991268
Find a, b and r for the following data using linear regression and
estimate x = ? for y =573 and y = ? for x = 19.
Data item 15 17 21 28
FREQ. 451 475 525 678
DEG STAT
1–VAR L I N LOG
[ MODE ] 2 [ ]
DEG STAT
DAT A 4 = 2 8 ,
[ ] [ DATA ] 15 [ ] 451 [ DATA ]
17 [
] 475 [ DATA ] 21 [ ] 525
[ DATA ] 28 [
] 678
678
REG
DEG STAT
a
[ 2nd ] [ a ]
176 . 106329114
REG
DEG STAT
b
[ 2nd ] [ b ]
17 . 5873417722
REG
DEG STAT
r
[ 2nd ] [ r ]
0 . 9 8984516413
REG
DEG STAT
x ’ 573
573 [ x ’ ]
22
. 5670073413
REG
DEG STAT
y ’ 19
19 [ y ’ ]
510
. 265822785
REG
Deleting data
The method to delete data depends on whether you have already
stored the data by next pressing [ DATA ] key or not.
To delete data you just input but have not yet stored it by next pressing
[ DATA ] , simple press [ CE ].
To delete data that you have already stored by next pressing
[ DATA ] ,
(A) To delete single–variable data using the following syntaxes :
# < x value > [ 2nd ] [ DEL ]
# < x value > [ x ] < Number of repeats > [ 2nd ] [ DEL ]
(B) To delete paired–variable / regression data using the following
syntaxes:
# Individual data-set : < x value > [
] < y value > [ 2nd ] [ DEL ]
# Multiple data-set with the same value :
< x value > [
] < y value > [ x ] < Number of repeats > [ 2nd ]
[ DEL ]
If you enter and delete a value that isn't included in the stored data by
mistake, " dEL Error " appears, but the previous data are still retained.
Editing data
Press [ 2nd ] [ EDIT ] to enter EDIT mode. The EDIT mode is
convenient and friendly for you to view, correct, delete data.
(A) In 1–VAR mode, the method to view data depends on whether you
want to view data item or not.
# Each time you press [ DATA ], first data item appears 1 second
and then the corresponding value.
[ DATA ]
DEG
dAtA 1
STAT
EDIT
1 second
DEG
15.
STAT
EDIT
# Each time you press [
], value appears directly on the
display without data item.
[
]
DEG
15.
STAT
EDIT
(B) In
REG mode, each time you press [ DATA ], data item and x value
appear on the screen at the same time. You can press [
] to
switch between x and y value.
[ DATA ]
DEG
DATA 1 = 15 , 45
STAT
15
EDIT
[ ]
DEG
DATA 1 = 15 , 45
STAT
451
EDIT
If you want to correct data, find out and enter a new entry to replace it.
FULL message
A “ FULL” is indicated when any of the following conditions occur and
further data entry becomes impossible. Just pressing any key can
Содержание
- Sr 281 sr 282 p.1
- Scientific calculator p.1
- Display readout p.1
- Contrast adjustment p.1
- Battery replacement p.1
- Auto power off function p.1
- Turning on or off p.1
- Reset operation p.1
- General guide p.1
- Replay function p.2
- Memory calculation p.2
- Corrections p.2
- Before starting calculation p.2
- Using mode keys p.2
- Using 2nd keys p.2
- Undo function p.2
- Order of operations p.3
- Accuracy and capacity p.3
- Arithmetic calculation p.4
- Error conditions p.4
- Basic calculations p.4
- Percentage calculation p.5
- Parentheses calculations p.5
- Display notations p.5
- Scientific functional calculations p.6
- And 2nd e p.6
- Perform the following operation to specify engineering symbol notation p.6
- 9 5 4 2 1 4 4 2 4 p.6
- Or the p.6
- 8 22 7 5 14 3 2 7 p.6
- Note values are automatically displayed in decimal format whenever the total number of digits of a fractional values integer numerator denominator separator marks exceeds 12 to enter a mixed number enter the integer part press a b c enter the numerator press a b c and enter the denominator to enter an improper fraction enter the numerator press a b c and enter the denominator p.6
- 100 06737947 p.6
- Mode 5 eng p.6
- 0 5714285714 p.6
- Logarithms and antilogarithms p.6
- Ln 7 log 100 3 4591014906 p.6
- Key by pressing 2nd p.6
- Fraction value display is as follow p.6
- Fraction calculation p.6
- Engineering symbol notation p.6
- Each time you specify the eng mode a displayed result is automatically shown with the corresponding engineering symbol p.6
- During a fraction calculation if the figure is reducible a figure is reduced to the lowest terms after pressing a function command key x or p.6
- Use main mode 1 main mode for scientific function calculations p.6
- Display of 5 p.6
- To exit from this mode press mode 5 once again p.6
- Display of p.6
- The calculator can calculate common and natural logarithms and anti logarithms using log ln 2nd 10 p.6
- D e the displayed value will be converted to the improper fraction and vice versa to convert between a decimal and fractional result press a b c p.6
- Trigonometric inverse tri functions p.7
- Sexagesimal decimal transformation p.7
- Hyperbolic inverse hyp functions p.7
- Angle unit conversions p.7
- Probability p.8
- Other functions 1 x p.8
- Int frac p.8
- Coordinates transformation p.8
- Unit conversion p.9
- Physics constants p.9
- Press const to display the physics constants menu 2 press p.11
- Or 2nd p.11
- 1 0664259841 x 10 p.11
- You also can use the const key in combination with a number 1 through 136 to recall a physical constants for example press 15 const p.11
- Until the constant you want is underlined 3 press p.11
- To insert a constant at the cursor position p.11
- Block function p.12
- Bases conversions p.12
- Base n calculations p.12
- Statistical calculations p.13
- Negative expressions p.13
- Logical operation p.13
- Entering data p.13
- Displaying results p.13
- Basic arithmetic operations for bases p.13
- Full message p.15
- Editing data p.15
- Deleting data p.15
- The results of a complex operation are displayed as follow p.16
- 7 9 i 15 12 i 22 3 i ab 22 036033112 ar 7 6516601843 p.16
- The unit complies with the requirements of directive 89 336 eec as amended by 93 68 eec p.16
- The number of repeats is more than 255 p.16
- Re real value im imaginary value p.16
- N 12750 appears when the times of data entry by data are up to 50 and the number of repeats for each value are all 255 i e 12750 50 x 255 p.16
- If the times of data entry by data is more than 50 p.16
- Complex mode enables you to add subtract multiply and divide complex numbers p.16
- Complex calculations p.16
- Clear the indicator the previous data entries are still retained unless you exit stat mode p.16
- Cbm bldg 5 68 10 nakano nakano ku tokyo 164 0001 japan tel 3 5345 7430 fax 3 5345 7431 citizen is a registered trademark of citizen watch co japan p.16
- Ab absolute value ar argument value p.16
Похожие устройства
-
Citizen WR3000Руководство по эксплуатации -
Citizen WR3000Техническое описание -
Citizen SRP-285NРуководство по эксплуатации -
Citizen SRP-285NТехническое описание -
Citizen SRP-265NРуководство по эксплуатации -
Citizen SRP-265NТехническое описание -
Citizen SR-281NРуководство по эксплуатации -
Citizen SR-281NТехническое описание -
Citizen SR-275EUТехническое описание -
Citizen SR-275EUРуководство по эксплуатации -
Citizen SR-135FGRРуководство по эксплуатации -
Citizen SR-135FGRТехническое описание