FAULT
CODE
MODULE DESCRIPTION POSSIBLE CAUSE SERVICE ACTION
P062F
ECM
ECM EEPROM faul
t-
exchange ECM
Damaged ECM. Replace ECM.
P06B6
ECM
ECM Fast ADC fa
ult
(knock detection line)
P1120
ECM
Throttle positions
calculated f
rom TPS
1 and TPS 2 not
corresponding
Damaged throt
tle
actuator, damaged
circuit wires, damaged
connector or
damaged
ECM
Check system circuit, perform
closed throttle with B.U.D.S.
Replace throttle actuator, replace ECM.
P1264
ECM
Ignition Power stage
overload
Damaged coi
l, damaged
circuit wires, damaged
connector or damaged
ECM output p
ins
Fault detected when
the engine is running
N/A
P1502
ECM
TOPS functional
problem
Boat or sensor upside
down, damaged
circuit w
ires, damaged
connector or damaged
ECM output pins
Check continuity for circuits A-C4,
A-G1, A-F4.
Refer to the Service Manual for
more details.
P1503
ECM
TOPS switch short
circuitto12V
Boat or sensor upside
down, damaged
circuit
wires, damaged
connector or damaged
ECM output pins
Check continuity for circuits A-C4,
A-G1, A-F4.
Refer to the Service Manual for
more details.
P1504
ECM
TOPS switch short
circuit ground
Boat or sensor upside
down, damaged
circui
t wires, damaged
connector or damaged
ECM output pins
Check continuity for circuits A-C4,
A-G1, A-F4.
Refer to the Service Manual for
more details.
P1505
ECM
TOPS switch fault
non plausible state
Boat or sensor upside
down, damaged
circu
it wires, damaged
connector or damaged
ECM output pin
Check continuity for circuits A-C4,
A-G1, A-F4.
Refer to the Service Manual for
more details.
P150
6
ECM
TOPS switch open
circuit
Boat or sensor upside
down, damaged
circ
uit wires, damaged
connector or damaged
ECM output pins
Check continuity for circuits A-C4,
A-G1, A-F4.
Refer to the Service Manual for
more details.
P1509
ECM
N/A N/A N/A
P1550
ECM
O.T.A.S. sensor
voltage not plausible
Damaged sensor,
damaged circuit wires,
damaged connector or
damaged ECM
Chec
k continuity for circuits B-H3,
B-H1 and FB1 -B5.
Refer to the Service Manual for
mor
e details.
P1606
ECM
ECM ADC fault -
exc
hange ECM
Damaged ECM
No service action available for fault
P1606.
206 smr2009-029