Ea2 BL503 — настройка времени и температуры: руководство пользователя [11/13]
![Ea2 BL503 [11/13] Manual time setting hold mode set button b6 for 3 seconds to enter clock calendar setting mode press b4 or b7 button to adjust the setting and press mode set button b6 to confirm each setting](/views2/1080222/page11/bgb.png)
ENGLISH 7 ENGLISH 8
8. Time and Alarm Setting
8.1 Manual Time Setting:
• Hold “MODE/SET” button (B6) for 3 seconds to enter Clock/Calendar setting mode.
• Press “-” (B4) or “+” (B7) button to adjust the setting and press “MODE/SET” button
(B6) to conrm each setting.
• The setting sequence is shown as follow: Hour, Minute, Second, Year, Month, Day,
Time Zone, Day-of-week language.
• 8 languages can be selected in Day-of-week, they are: German, French, Spanish,
Italian, Dutch, Denmark, Russian, and English.
• The languages and their selected abbreviations for each day of the week are shown in
the following table.
• For Time Zone: If you receive no RC-DCF frequency signal, the time zone should be
set to 0. Time Zone is used in countries which can received the DCF frequency signal
but the time zone is different from German Time ( i.e. GMT+1).
Note:
(1) Second adjusted to zero only.
(2) The Time Setting Mode will automatically exit in 15 seconds without any adjustment.
8.2 12/24 Hour Display mode:
Press “(12/24)” button (B7) to select 12 or 24 hours mode.
7.2 Temperature & Humidity
(1) Outdoor Temperature--- Channel Selection
• Press “CHANNEL” button (B8) to view the 3 Channel’s temperature. The sequence is
shown as follow:
PRESS “CHANNEL” button > PRESS “CHANNEL” button > PRESS “CHANNEL” button
• When viewing the record on CHANNEL 1 or 2, or 3, hold “CHANNEL” button (B8) for 3
seconds to cancel the record on this channel manually, and receive the transmission
from channels automatically again.
(2) Outdoor Temperature Trend
• The trend pointer (A6) displayed on the LCD indicates the trend of the outdoor
temperature.
(3) Celsius / Fahrenheit
• Press “°C /°F” button (B4) to select Indoor/Outdoor Temperature in Celsius mode or
Fahrenheit mode.
• If the temperature is out of the measurable range, LL.L (beyond the minimum
temperature) or HH.H (beyond the maximum temperature) will be shown on the LCD.
(4) Maximum / Minimum Temperature & Indoor Humidity Recording Function:
• Press “MAX/MIN” button (B3) to show the maximum recorded Indoor /Outdoor
Temperature and Indoor Humidity. “ ” is shown on the LCD
• Press “MAX/MIN” button again to show the minimum recorded Indoor/Outdoor
Temperature and Indoor Humidity. “ ” is shown on the LCD.
• Hold “MAX/MIN” button (B3) for 3 seconds to clear the recorded maximum and
minimum reading.
Indicating the outdoor
temp. is rising
Indicating the outdoor
temp. is steady
Indicating the outdoor
temp. is falling
Language Sunday Monday Tuesda
Wednesday
Thursday Friday Saturday
German, GE SO MO DI MI DO FR SA
English, EN SU MO TU WE TH FR SA
Russian, RU BC ПН BT CP ЧТ ПТ СБ
Denmark, DA SO MA TI ON TO FR LO
Dutch, NE ZO MA DI WO DO VR ZA
Italian, IT DO LU MA ME GI VE SA
Spanish, ES DO LU MA MI JU VI SA
French, FR
DI LU MA ME JE VE SA
OUT OUT
OUT
Display the three
channels alternatively
Содержание
- Bl503 тонкая погодная станция с измерением температуры влажности и часами p.2
- Основное устройство p.3
- Свойства p.3
- Начало работы p.4
- Установка p.4
- Дистанционный датчик p.4
- Прогноз погоды p.4
- Термометр p.5
- Out out p.5
- Настройка часов будильника p.6
- Дистанционный датчик p.7
- Погодная станция p.7
- Технические характеристики p.7
- Индикатор низкого заряда батарей p.7
- Меры предосторожности p.7
- Подсветка p.7
- User manual p.8
- Slim wireless weather station with temperature and humidity p.8
- Features p.8
- Main unit appearance 3 outdoor thermo sensor p.9
- Getting started p.9
- Weather forecast function p.10
- Thermometer p.10
- Installation p.10
- Manual time setting hold mode set button b6 for 3 seconds to enter clock calendar setting mode press b4 or b7 button to adjust the setting and press mode set button b6 to confirm each setting p.11
- Temperature humidity 1 outdoor temperature channel selection press channel button b8 to view the 3 channel s temperature the sequence is shown as follow p.11
- 4 maximum minimum temperature indoor humidity recording function press max min button b3 to show the maximum recorded indoor outdoor temperature and indoor humidity is shown on the lcd p.11
- When viewing the record on channel 1 or 2 or 3 hold channel button b8 for 3 seconds to cancel the record on this channel manually and receive the transmission p.11
- 3 celsius fahrenheit press c f button b4 to select indoor outdoor temperature in celsius mode or fahrenheit mode p.11
- Time and alarm setting p.11
- 24 hour display mode press 12 24 button b7 to select 12 or 24 hours mode p.11
- The setting sequence is shown as follow hour minute second year month day time zone day of week language p.11
- 2 outdoor temperature trend the trend pointer a6 displayed on the lcd indicates the trend of the outdoor temperature p.11
- The languages and their selected abbreviations for each day of the week are shown in the following table p.11
- Press max min button again to show the minimum recorded indoor outdoor temperature and indoor humidity is shown on the lcd p.11
- Out out p.11
- Note 1 second adjusted to zero only 2 the time setting mode will automatically exit in 15 seconds without any adjustment p.11
- If the temperature is out of the measurable range ll l beyond the minimum temperature or hh h beyond the maximum temperature will be shown on the lcd p.11
- Hold max min button b3 for 3 seconds to clear the recorded maximum and minimum reading p.11
- From channels automatically again from channels automatically again p.11
- For time zone if you receive no rc dcf frequency signal the time zone should be set to 0 time zone is used in countries which can received the dcf frequency signal p.11
- But the time zone is different from german time i e gmt 1 but the time zone is different from german time i e gmt 1 p.11
- 8 languages can be selected in day of week they are german french spanish italian dutch denmark russian and english p.11
- Backlight p.12
- Specifications p.12
- Precautions p.12
- Outdoor data p.12
- Low battery indication p.12
- Indoor data p.12
- Battery requirements p.12
Похожие устройства
-
Ea2 BL502Инструкция по эксплуатации -
Ea2 ED609Инструкция по эксплуатации -
Ea2 BL508Инструкция по эксплуатации -
МЕГЕОН 20205Инструкция к устройству -
Oregon Scientific WMR500Руководство пользователя -
Uniel UTV-63Руководство по эксплуатации -
Kitfort КТ-3378Инструкция по эксплуатации -
Kitfort КТ-3377Инструкция по эксплуатации -
Kitfort КТ-3732Инструкция по эксплуатации -
Kitfort КТ-3729Инструкция по эксплуатации -
Kitfort КТ-3735Инструкция по эксплуатации -
Kitfort КТ-3736Инструкция по эксплуатации
Узнайте, как настроить время, температуру и влажность с помощью простых шагов. Подробное руководство по выбору языков и режимов отображения.