RS-485 PUSHBUTTON CONTROL PANELS
13
The two connectors on the back of the control panel are connected in parallel. This
allows the panels to be looped (“daisy chained”) together. If it is more convenient, you
can build a fan-out panel or box so that only one cable needs to run to each panel. In
either case, the total cable length cannot exceed 5,000 feet at 31,250 baud or 10,000 feet
at 9,600 baud.
If you make your own interconnect cables, Pin 2 is Ground. Pin 1 and 3 connect pin for
pin.
Warning!
Lights “scrolling” on a panel indicate that the panel is not communicating with the router. Check
the control panel cable and baud rate settings.
Output and Level Setup
The output(s) and levels the control panel will switch can be setup using the Sierra Video
TyLinx Pro software.
Follow the instructions in the TyLinx Pro manual to retrieve the router settings and
discover the control panels connected to the router.
If new control panels are added select “ReSync” on the device map screen of TyLinx Pro
to discover the new panels.